3.3 Power-Up / Power-Down Scenarios
s
AC65_AC75_HD_v01.002 Page 31 of 117 2006-10-30
Confidential / Released
Figure 6: Power-on with IGT held low before switching on operating voltage at BATT+
If the IGT line is driven low for less than 400ms the module will, instead of starting up, send only the alert mes-
sage "SHUTDOWN after Illegal PowerUp" to the host application. The alert message appears on the serial inter-
faces ASC0 and ASC1 at a fixed bit rate of 115200bps. If other fixed bit rates or autobauding are set, the URC
delivers only undefined characters. The message will not be indicated on the USB interface.
EMERG_RST
PWR_IND
t = 400ms
min
>
120ms
BATT+
IGT
HiZ
VEXT
TXD0/TXD1/RTS0/RST1/DTR0 (driven by the application)
CTS0/CTS1/DSR0/DCD0
ca. 500 ms
Interface pins
Undefined
Defined
For details on how to use EMERG_RST to reset applications
or external devices see Section 3.3.1.6.