Printer User Manual

2 out of 5 Industrial Barcodes
Programmer Reference Guide U26169-J-Z716-1-7600
© Siemens Nixdorf Informationssysteme AG 1995 Pfad: D:\SNI\Mackwitz\u26169\o26169e\26169E.K06
The blank zone before and after the barcode symbol should be at least 10 times the width
of a narrow element.
Reference table for check digit calculation:
Example of check digit calculation modulo 43:
2 out of 5 Industrial
The character complement of the 2 out of 5 Industrial code comprises:
10 digits: 0 1 2 3 4 5 6 7 8 9
Start/stop characters: :/; </=
The number of characters is variable.
The start/stop characters are programmed with the characters : and ;. Alternatively, the
characters < and = can be used as start/stop characters.
In the plain text line, the characters . and ; or < and = are printed for start/stop.
The symbol layout is self-checking. A check digit is not required but should be used (modulo
10 with a weighting of 3). The check digit must be programmed in the application.
The ratio of wide to narrow elements should be between 2.0 and 3.0. A ratio of 2.5 is recom-
mended for applications.
The code permits large tolerances between ±15% and 20%.
The blank zone before and after the barcode symbol should be at least 10 times the width
of a narrow element.
0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
A
10
B
11
C
12
D
13
E
14
F
15
G
16
H
17
I
18
J
19
K
20
L
21
M
22
N
23
O
24
P
25
Q
26
R
27
S
28
T
29
U
30
V
31
W
32
X
33
Y
34
Z
35
-
36
.
37
Sp
38
$
39
/
40
+
41
%
42
Information characters : CODE 39
Sum of reference digits : 12+24+13+14+38+3+9=113
Modulo 43 : 113 mod 43 = 27 (113/43 = rem. 27)
Check digit : 27