Printer User Manual
Font design Epson LQ-2550 emulation
Programmer Reference Guide U26169-J-Z716-1-7600
© Siemens Nixdorf Informationssysteme AG 1995 Pfad: D:\SNI\Mackwitz\u26169\o26169e\26169e.k05
Define user-defined characters
One or several characters can be defined. If the current character set was loaded in the
user-defined character set beforehand, the characters defined by this command are
replaced.
p
1
specifies the code location of the first character to be defined
p
2
specifies the code location of the last character to be defined
p
3
specifies the number of leading blank columns of the character to be defined
p
4
specifies the number of dot columns of the character to be defined
p
5
specifies the number of trailing blank columns of the character to be defined
Data Data bytes containing the dot information
Control sequence Hexadecimal Decimal
ESC & NUL p
1
p
2
p
3
p
4
p
5
data
1B 26 00 p
1
p
2
p
3
p
4
p
5
data
27 38 00 p
1
p
2
p
3
p
4
p
5
data
Range: X’00 to X’7F
Range: p
1
to X’7F
Range: X’00 to X’2A (1 to 42 columns)
Range: X’00 to X’25 (1 to 37 columns)
Range: X’00 to X’2A (1 to 42 columns)
Range: X’00 to X’FF (any bit of a byte may be 1 (dot) or 0
(no dot))