Data Sheet for Product

7MF15654 Pressure Transmitter, PSIG Range for Sensing Liquid/Gas Technical Instructions
Document Number 155-768
September 16, 2021
Siemens Industry, Inc. Page 3
Measuring range ≥1 bar
(≥14.5 psi)
The thin-film measuring cell has a thin-film resistance bridge to which the operating
pressure p is transmitted through a ceramic diaphragm.
The measuring cell output voltage is converted by an amplifier into an output current.
The output is linearly proportional to the input pressure.
Specifications
Mode or Operation
Measuring range Piezo-resistive
<1 bar (<14.5 psi)
Measuring range Thin-film strain gauge
>1 bar (<14.5 psi)
Input Media Range
Measured variable Gauge pressure
Measured range
Pressure 0 to 300 psi g (0 to 21 bar g)
Output Signal
Current output signal 4 to 20 mA
Voltage output signal 0 to 10 Vdc
Accuracy
To EN 60770-1
Error in measurement (at 77°F [2C]), 0.25% of full-scale value typical
including conformity error, hysteresis and
repeatability
Response time T
99
< 0.1 second
Long-term drift
Start of scale 0.25% of full scale value/year
Full-scale value 0.25% of full scale value/year
Influence of ambient temperature
Start of scale 0.25%/10 K of full-scale value
Full-scale value 0.25%/10 K of full-scale value
Rated Operating
Conditions
Process temperature -22°F to 248°F (-30°C to 12C)
Ambient temperature -13°F to 185°F (-25°C to 84°F)
Storage temperature -58°F to 212°F (-50°C to 10C)
Degree of protection to EN60529 IP65
Design
Weight 0.55 lb (≈ 0.25 kg)
Wetted parts materials:
Measuring cell
Measuring range < 1 bar (< 14.5 psi) Stainless steel, 1.456 1/316Ti
Measuring range > 1 bar (> 14.5 psi) AI
2
O
3
96%
Process connection Stainless steel, mat. No. 1.4571/316Ti
Gasket Viton
Input Power Supply U
H
Terminal voltage on pressure transmitter
For current output 10 to 36 Vdc