Datasheet

Mechanical Design
Mounting position vertical
Mounting type / panel mounting No
Net weight 754g
Environmental conditions
Degree of pollution 2
Installation altitude / at height above sea level /
maximum
2000m
Standard
● for EMC for industrial sector
IEC 61000-6-2
● for EMC against unloading
IEC 61000-4-2 - 6 kV contact discharge; 8 kV air discharge
● for EMC against high frequency fields
IEC 61000-4-3 80 MHz up to 3 GHz, 10 Vm
● for EMC against conducted LF disturbance
variables (industry)
IEC 61000-6-4
● for EMC against conducted disturbance
variables via HF fields
IEC 61000-4-6; 2008; 0.15 MHz - 80 MHz
● for EMC against magnetic fields with power
engineering frequencies
IEC 61000-4-8, Class IV
● for EMC against quick, transient electrical
disturbances
IEC 61000-4-4 Class 3; 2 kV, 5 KHz
● for EMC against voltage drops and
interruptions
IEC 61000-4-11; 2004-03
● for EMC against surge voltages
IEC 61000-4-5 installation class 2, 2 kV/1 kV,
● for free fall
IEC 60068-2-31
● for cyclic, environmental damp heat check
IEC 60068-2-78 Test Ca
● for environmental coldness check
IEC 60068-2-1 Test Ad
● for environmental dry heat check
IEC 60068-2-2 Test Bd
Relative humidity / at 25 °C / without condensation /
during operation
● minimum
75%
● maximum
95%
Ambient temperature
● during operation / minimum
-25°C
● during operation / maximum
55°C
● during storage / minimum
-40°C
● during storage / maximum
70°C
Certificates
Certificate of suitability
● as EC declaration of conformity
EN 61000-6-2 and EN 61000-6-4 for EMC guideline
● as approval for USA
UL - File E228586, Vol. X1: A1
7KM5412-6CA00-1EA8 Subject to change without notice
Page 5/
8
01/14/2019 © Copyright Siemens