Datasheet

● of the characteristic impedance at 3 MHz … 20
MHz
10%
Loop resistance per length / maximum 110mΩ/m
Shield resistance per length / maximum 9.5Ω/km
Capacity per length / at 1 kHz 28.5pF/m
Operating voltage
● RMS value
100V
Mechanical data
Number of electrical cores 2
Design of the shield Overlapped aluminum-clad foil, sheathed in a braided screen of
tin-plated copper wires
Type of electrical connection / FastConnect Yes
Outer diameter
● of inner conductor
0.65mm
● of the wire insulation
2.55mm
● of the inner sheath of the cable
5.4mm
● of cable sheath
8mm
Symmetrical tolerance of the outer diameter / of
cable sheath
0.4mm
Material
● of the wire insulation
PE
● of the inner sheath of the cable
PVC
● of cable sheath
PVC
Color
● of the insulation of data wires
red / green
● of cable sheath
Violet
Bending radius
● with single bend / minimum permissible
37.5mm
● with multiple bends / minimum permissible
75mm
Tensile load / maximum 100N
Weight per length 80kg/km
Permitted ambient conditions
Ambient temperature
● during operation
-40...+75°C
● during storage
-40...+75°C
● during transport
-40...+75°C
● during installation
-40...+75°C
● Note
electrical properties measured at 20 Cel, tests according to DIN
47250 part 4 respectively DIN VDE 0472
Burning behavior flame resistant according to IEC 60332-3-24 (Category C) and UL
1685 (CSA FT 4)
Chemical resistance
6XV1830-0EH10 Changes preserved
Page 2/
3
23.07.2015 © Copyright Siemens AG