Datasheet

6SL3210-1KE13-2AP2
Data sheet for SINAMICS G120C
MLFB-Ordering data
Figure similar
Switching level: 1→0
Standard digital inputs
Number
Max. inrush current
Switching level: 0→1
Inputs / outputs
Fail-safe digital inputs
Number
Digital outputs
Number as transistor
Output (resistive load)
Number as relay changeover contact
Output (resistive load)
Analog / digital inputs
Number
Compliance with standards
CE marking
Standards
Number
Analog outputs
PTC/ KTY interface
1
15 mA
11 V
6
1
1
EMC Directive 2004/108/EC, Low-Voltage
Directive 2006/95/EC
UL, cUL, CE, C-Tick (RCM)
1 motor temperature sensor input, sensors that can be connected: PTC, KTY
and Thermo-Click, accuracy ±5 °C
DC 30 V, 0.5 A
DC 30 V, 0.5 A
1 (Differential input)
Mechanical data
155 mm (6.10 in)
Degree of protection IP20 / UL open type
73 mm (2.87 in)
Height
Net weight 1.40 kg (3.09 lb)
Depth
Size
Width
173 mm (6.81 in)
FSAA
Signal cable
Plug-in screw terminals
Version
Version
Unshielded 100 m (328.08 ft)
Conductor cross-section
Conductor cross-section
1.00 ... 2.50 mm² (AWG 18 ... AWG 14)
Version
1.00 ... 2.50 mm² (AWG 18 ... AWG 14)
Max. motor cable length
Conductor cross-section
Connections
Plug-in screw terminals
Motor end
50 m (164.04 ft)
On housing with M4 screw
Line side
PE connection
Conductor cross-section
DC link (for braking resistor)
5 V
Plug-in screw terminals
1.00 ... 2.50 mm² (AWG 18 ... AWG 14)
Shielded
0.15 ... 1.50 mm² (AWG 24 ... AWG 16)
1 (Non-isolated output)
Line length, max. 15 m (49.21 ft)
4 V0→1
1→0 1.6 V
10 bitResolution
Switching threshold as digital input
Communication PROFIBUS DP
Communication
Technical data are subject to change! There may be discrepancies between calculated and rating plate values.
Generated Wed Jan 09 10:32:44 CET 2019