Datasheet

● external / minimum
18V
● external / maximum
31.2V
Product component / fusing at power supply input Yes
Fuse protection type / at input for supply voltage 0.5 A / 60 V
Consumed current / maximum 0.06A
Power loss [W]
● at DC / at 24 V
1.44W
Permitted ambient conditions
Ambient temperature
● during operation
-40...+70°C
● during storage
-40...+85°C
● during transport
-40...+85°C
Relative humidity
● at 25 °C / without condensation / during
operation / maximum
95%
Protection class IP IP20
Design, dimensions and weight
Design compact
Width 35mm
Height 152mm
Depth 135mm
Net weight 0.24kg
Mounting type Installation with a stand and in 19" rack using accessory
components
● 35 mm DIN rail mounting
Yes
● wall mounting
Yes
● S7-300 rail mounting
Yes
● S7-1500 rail mounting
Yes
Product functions / Redundancy
Product function
● Parallel Redundancy Protocol (PRP)/operation
in the PRP-network
Yes
● Parallel Redundancy Protocol
(PRP)/Redundant Network Access (RNA)
No
Standards, specifications, approvals
Standard
● for FM
FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2,
GP. IIC, T4
● for hazardous zone
EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc,
KEMA 07ATEX0145 X
● for safety / from CSA and UL
UL 60950-1, CSA C22.2 No. 60950-1
● for emitted interference
EN 61000-6-4 (Class B)
6GK5104-0BA00-1SA2 Subject to change without notice
Page 2/
3
12/14/2018 © Copyright Siemens