User Manual

2 / 8
Siemens CP 343-1 BACnet – 6FL4343-1CX10-0XE0 CM1N9291en_02
Building Technologies 17 Sep 2009
Engineering with NCM S7 for Ethernet (integrateable as of STEP 7 Version
V5.4 SP4 HF6 ).
Cross-network PD/OP communications using S7 routing.
Diagnostic functions in STEP 7 and via web browser.
Direct integration of S7-300 in complex plants over Ethernet at 100 Mbps.
Ideal for deployment on line-structure networks using integrated 2-port
real-time switch.
Investment protection for existing plants by integrating SIMATIC S7-300
via S5-compatible communications.
Flexible use thanks to free port selection.
Saving space required for integration thanks to single-width design.
Remote programming possible also via telephone network (e.g. ISDN)
thanks to TCP/IP's WAN properties.
Multicast function to reach many members.
Access of max. 4 operating and monitoring systems to SIMATIC S7-300.
Use of socket interface in partner system possible without RFC 1006.
Initial commissioning direct via Industrial Ethernet.
Use of uncrossed connecting lines possible thanks to integrated auto
crossover function.
Secure data communications via industrial-type device connection with IE
FC RJ45 plug 145/180 plug connector and additional strain relief thanks to
latching the connector to the housing.
Functions
The CP 343-1 BACnet handles all data traffic over Ethernet.
The module has its own processor. Layers 1 to 4 comply with international
standards.
Multi-protocol operation of transport protocols TCP/IP and UDP as well as BACnet
is possible.
The CP 343-1 BACnet has a preset, unique Ethernet address, allowing for
commissioning via network.
The CP 343-1 BACnet works in multi-protocol mode for the following
communications services:
BACnet (Building Automation Control Network) is a standardized layer 7-protocol
for building automation and control as per EN 16484, Part 5. It comprises:
Standardized services processed autonomously by the CP.
Standardized objects representing the user's view of automation and control.
The CP 343-1 is used with two market offering packages:
DESIGO S7 Building Solution allows for using SIMATIC S7 within the DESIGO
system together with an S7-HVAC library following the DESIGO PX library.
Communications is via BACnet. Using an HVAC library allows for efficient
engineering of HVAC applications.
DESIGO S7 Building Integration integrates existing SIMATIC S7 (software
without SBT HVAC LIB) in a DESIGO system over BACnet communications.
This allows for efficient integration. BACnet objects and their mapping to S7 data
is carried out in a mapping tool.
BACnet
communications