User Manual
Motion control is easy   
10.7 Commissioning 
  Easy Book 
254  Manual, 03/2014, A5E02486774-AF 
Error 
Description 
Max software limit exceeded  The upper software limit switch has been exceeded. 
(Tag of technology object: <Axis name>.ErrorBits.SwLimitMaxExceeded) 
Negative hardware limit  The lower hardware limit switch has been approached. 
(Tag of technology object: <Axis name>.ErrorBits.HwLimitMin) 
Positive hardware limit  The upper hardware limit switch has been approached. 
(Tag of technology object: <Axis name>.ErrorBits.HwLimitMax) 
PTO already used  A second axis is using the same PTO and is enabled with "MC_Power". 
(Tag of technology object: <Axis name>.ErrorBits.HwUsed) 
Configuration error  The "Axis" technology object was incorrectly configured or editable configuration data 
were modified incorrectly during runtime of the user program. 
(Tag of technology object: <Axis name>.ErrorBits.ConfigFault) 
General Error  An internal error has occurred. 
(Tag of technology object: <Axis name>.ErrorBits.SystemFault) 
"Motion status" diagnostic function 
Use the "Motion status" diagnostic function to monitor the motion status of the axis. The 
diagnostic function display is available in online mode in "Manual control" mode and in 
"Automatic control" when the axis is active. 
Table 10- 45  Motion status 
Status 
Description 
Target position  The "Target position" field indicates the current target position of an active positioning task of 
motion control instruction "MC_MoveAbsolute" or "MC_MoveRelative" or of the control panel. 
The value of the "Target position" is only valid during execution of a positioning task. 
(Tag of technology object: <Axis name>.MotionStatus.TargetPosition) 
Current position  The "Current position" field indicates the current axis position. If the axis is not homed, the 
value indicates the position value relative to the enable position of the axis. 
(Tag of technology object: <Axis name>.MotionStatus.Position) 
Current velocity  The "Current velocity" field indicates the actual axis velocity. 
(Tag of technology object: <Axis name>.MotionStatus.Velocity) 
Table 10- 46  Dynamic limits 
Dynamic limit 
Description 
Velocity  The "Velocity" field indicates the configured maximum velocity of the axis. 
(Tag of technology object: <Axis name>.Config.DynamicLimits.MaxVelocity) 
Acceleration  The "Acceleration" field indicates the currently configured acceleration of the axis. 
(Tag of technology object: <Axis name>.Config.DynamicDefaults.Acceleration) 
Deceleration  The "Deceleration" field indicates the currently configured deceleration of the axis. 
(Tag of technology object: <Axis name>.Config.DynamicDefaults.Deceleration) 