User Manual
  Programming LOGO! 
  3.7 Writing and starting the circuit program 
LOGO! 
Manual, 04/2011, A5E03556174-01 
87 
Press OK to confirm your entries and exit the dialog. 
4
Bุ
%
4
%
ุ
<RXUFRPSOHWHFLUFXLWSURJUDPOD\RXW7KHGLVSOD\QRZVKRZV
%ORFN
QXPEHU
You have now entered the first block. Each new block is automatically assigned a block 
number. The only thing left to do is interconnect the block inputs. This is how it is done: 
Press OK. 
4
ൻ&Rุ
%
7KHGLVSOD\QRZVKRZV
Select the Co list: Press OK 
4
[ุ
%
7KHGLVSOD\QRZVKRZV
The first element of the Co list is the "Input 1" character, namely "I1". 
Note 
Press 
 to go to the start of the Co list: I1, I2 ... to lo. Press   to go to the end of the Co list: 
lo, hi, ... to I1. 
Inputs F1, F2, F3, and F4 are new as of the 0BA6 device series. They correspond to the four 
function keys on the optional LOGO! TD. 
More shift register bits (S1.1 to S4.8), blank connectors (X1 to X64) and analog flags (AM1 
to AM16) are available in the 0BA7 device series. 
Network digital inputs (NI1 to NI64), network analog inputs (NAI1 to NAI32), network digital 
outputs (NQ1 to NQ64), and network analog outputs (NAQ1 to NAQ16) are new connectors 
for the 0BA7 device series. They are not preconfigured in the LOGO! 0BA7. You can only 
configure them from LOGO!Soft Comfort V7.0 for a circuit program and download the 
program to the LOGO! 0BA7 to make them available in your LOGO! 0BA7 device. 