● Interference immunity on supply cables
±2 kV acc. to IEC 61000-4-4, burst; ±1 kV acc. to IEC 61000-4-5,
surge symmetric; ±2 kV acc. to IEC 61000-4-5, surge asymmetric
● Interference immunity on signal cables >30m
±2 kV acc. to IEC 61000-4-5, surge, length > 30 m
● Interference immunity on signal cables < 30m
±1 kV acc. to IEC 61000-4-4; burst; length < 3 m; ±2 kV acc. to
IEC 61000-4-4; burst; length > 3 m
Interference immunity against voltage surge
● asymmetric interference
±2 kV acc. to IEC 61000-4-5, surge asymmetric
● symmetric interference
±1 kV acc. to IEC 61000-4-5, surge symmetric
Interference immunity to magnetic fields
● Interference immunity to magnetic fields at 50
Hz
100A/m; to IEC 61000-4-8
Emission of conducted and non-conducted interference
● Interference emission via line/AC current
cables
EN 61000-6-3, EN 61000-6-4, CISPR 22 Class B, FCC Class A
Degree and class of protection
IP (at the front) IP20
IP (rear) IP20
Standards, approvals, certificates
CE mark Yes
UL approval Yes
● UL 508
Yes
cULus Yes
RCM (formerly C-TICK) Yes
KC approval Yes
FCC Yes
EMC CE, EN 61000-6-3:2007 +A1:2011, EN 61000-6-2:2005
Marine approval
● Germanischer Lloyd (GL)
Yes
● American Bureau of Shipping (ABS)
Yes
● Bureau Veritas (BV)
Yes
● Det Norske Veritas (DNV)
Yes
● Lloyds Register of Shipping (LRS)
Yes
● Nippon Kaiji Kyokai (Class NK)
Yes
Ambient conditions
Ambient temperature during operation
● Ambient temperature during operation
+5 °C up to 55 °C
Ambient temperature during storage/transportation
● min.
-20°C
● max.
60°C
Relative humidity
6AG4131-2EB10-0AC6 Subject to change without notice