Data Sheet
Retentive data area (incl. timers, counters, flags),
max.
2Mbyte; 128 KB can be stored in the buffer time; optional
Hardware configuration
Slots
● free slots
2x PCI; optional: 1x PCI & 1x PCIe (x16); 2x PCIe (x4, x16); with
card retainer
● Number of PCI slots
2; Optional
● Number of PCI slots
2; Optional
Interfaces
PROFIBUS/MPI Optionally onboard, isolated, max. 12 Mbit/s, compatible with CP
5622
Number of industrial Ethernet interfaces 2; 2x RJ45 (independent)
Number of PROFINET interfaces 3; Optional
USB port 4x USB 3.0
Connection for keyboard/mouse USB / USB
serial interface 1x COM1 (RS 232), optional: 1x COM2 (RS 232)
parallel interface optional LPT1
Video interfaces
● Graphics interface
1x DisplayPort and 1x DVI-I; 1x VGA via adapter cable (optional)
Industrial Ethernet
● Industrial Ethernet interface
Onboard, 2x 10 / 100 / 1000 Mbit, RJ45
— 100 Mbps
Yes
— 1000 Mbps
Yes
Interrupts/diagnostics/status information
Bus diagnostics Yes
Integrated Functions
Monitoring functions
● Temperature monitoring
Yes
● Watchdog
Yes
● Status LEDs
Yes
● Fan
Yes
● Monitoring function via network
Optional
EMC
Interference immunity against discharge of static electricity
● Interference immunity against discharge of
static electricity
±6 kV contact discharge acc. to IEC 61000-4-2; ±8 kV air
discharge acc. to IEC 61000-4-2
Interference immunity against high-frequency electromagnetic fields
● Interference immunity against high frequency
radiation
10 V/m for 80 - 1 000 MHz and 1.4 - 2 GHz, 80% AM acc. to IEC
61000-4-3; 3 V/m for 2 - 2.7 GHz, 80% AM acc. to IEC 61000-4-3;
10 V for 10 kHz - 80 MHz, 80% AM acc. to IEC 61000-4-6
Interference immunity to cable-borne interference
6AG4131-2EB10-0AC6 Subject to change without notice
Page 2/
4
09/13/2019 © Copyright Siemens