Specifications

60 Chapter 6
Cabling the XMU+
AT&T System 75/85
Ericsson MD 110
PAB X
Signal
Announcer
Signal
Line 1
Pin-
Color
Line 2
Pin-
Color
Line 3
Pin-
Color
Line 4
Pin-
Color
Line 5
Pin-
Color
Line 6
Pin-
Color
Line 7
Pin-
Color
Line 8
Pin-
Color
Ring Ring
1 -
Blu/Wht
4 -
Brn/Wht
7 -
Org/Red
10 -
Slt/Red
13 -
Grn/Blk
16 -
Blu/Yel
19 -
Brn/Yel
22 -
Org/Vlt
Tip Tip
26 -
Wht/Blu
29 -
Wht/Brn
32 -
Red/Org
35 -
Red/Slt
38 -
Blk/Grn
41 -
Ye l / B l u
44 -
Ye l / B r n
47 -
Vlt/Org
Battery* Start-
28 -
Wht/Grn
31 -
Red/Blu
34-
Red/Brn
37 -
Blk/Org
40 -
Blk/Slt
43 -
Ye l / G r n
46 -
Vlt/Blu
49 -
Vlt/Brn
SStart+
3 -
Grn/Wht
6 -
Blu/Red
9 -
Brn/Red
12 -
Org/Blk
15 -
Slt/Blk
18 -
Grn/Yel
21 -
Blu/Vlt
24 -
Brn/Vlt
AL1 CP1
27 -
Wht/Org
30 -
Wht/Slt
33 -
Red/Grn
36 -
Blk/Blu
39 -
Blk/Brn
42 -
Ye l / O r g
45 -
Ye l / S l t
48 -
Vlt/Grn
Ground CP2
2 -
Org/Wht
5 -
Slt/Wht
8 -
Grn/Red
11 -
Blu/Blk
14 -
Brn/Blk
17 -
Org/Yel
20 -
Slt/Yel
23 -
Grn/Vlt
PBX Operation Mode: Pulse Start/Level Return (PS/LR NO). See
About XMU+ Operating Modes
on page 68 for more
information.
Ground must come from Circuit Pack.
PAB X
Signal
Announcer
Signal
Line 1
Pin-
Color
Line 2
Pin-
Color
Line 3
Pin-
Color
Line 4
Pin-
Color
Line 5
Pin-
Color
Line 6
Pin-
Color
Line 7
Pin-
Color
Line 8
Pin-
Color
T Rec Ring
1 -
Bl u/ Wh t
4 -
Brn/Wht
7 -
Org/Red
10 -
Slt/Red
13 -
Grn/Blk
16 -
Blu/Yel
19 -
Brn/Yel
22 -
Org/Vlt
R Tx Tip
26 -
Wht/Blu
29 - Wht/
Brn
32 -
Red/Org
35 -
Red/Slt
38 -
Blk/Grn
41 -
Ye l / B l u
44 -
Ye l / B r n
47 -
Vlt/Org
MStart-
28 -
Wht/Grn
31 -
Red/Blu
34 -
Red/Brn
37 -
Blk/Org
40 -
Blk/Slt
43 -
Ye l / G r n
46 -
Vlt/Blu
49 -
Vlt/Brn
Aux.
GND
Start+
3 -
Grn/Wht
6 -
Blu/Red
9 -
Brn/Red
12 -
Org/Blk
15 -
Slt/Blk
18 -
Grn/Yel
21 -
Blu/Vlt
24 -
Brn/Vlt
S -GND CP1
27 -
Wht/Org
30 -
Wht/Slt
33 -
Red/Grn
36 -
Blk/Blu
39 -
Blk/Brn
42 -
Ye l / O r g
45 -
Yel / S l t
48 -
Vlt/Grn
ECP2
2 -
Org/Wht
5 -
Slt/Wht
8 -
Grn/Red
11 -
Blu/Blk
14 -
Brn/Blk
17 -
Org/Yel
20 -
Slt/Yel
23 -
Grn/Vlt
PBX Operation Mode: Pulse Start/Level Return Single Play (PS/LR SP NO). See
About XMU+ Operating Modes
on page 68
for more information.
MD 110 is set to type II 2 wire. Var=00, Type=RA1
Connect S - Batt from PABX to Aux - Batt