Specifications
XMU+ Installation and Maintenance Guide rev.07 137
Detailed XMU+ Technical Specifications
Detailed XMU
+
Technical Specifications
The following tables describe the technical features of the XMU+. These XMU+ features
are approximate, and are subject to change without notice.
System Specifications
Technical Feature... Details...
Physical
Unit Dimensions:
Large chassis: 177 x 444 x 330 mm (7.0 x 17.5 x 13.0 inches)
Small chassis: 44 x 444 x 330 mm (1.75 x 17.5 x 13.0 inches)
Rack Space:
Large chassis: 4 units
Small chassis: 1 unit
Shipping
Dimensions:
Large chassis: 260 x 500 x 500 mm (10.25 x 19.7 x 19.7
inches)
Small chassis: 107 x 540 x 455 mm (4.3 x 21.3 x 18.0 inches)
Unit Maximum
Weig ht:
Large chassis: 9.4 Kg (20.7 pounds)
Small chassis: 3.1 Kg (6.9 pounds)
Shipping Maximum
Weig ht:
Large chassis: 12.9 Kg (28.4 pounds)
Small chassis: 6.2 Kg (13.6 pounds)
Power and Thermal
Power Consumption:
Large Chassis: 220 Watts maximum
Small Chassis: 50 Watts maximum
Heat Production:
Large Chassis: 220 Watts (750 BTU/hr) maximum
Small Chassis: 50 Watts (160 BTU/hr) maximum
Note: BTU/hr = Consumption in Watts x 3.415
Environmental
Te mp eratur e:
0 - 40 degrees
o
C (32 - 104
o
F) temperature range. Adequate
cooling or heating must be provided to guarantee this range.
Dust: Units not for operation in conductive dust atmospheres (i.e.
coal dust, metal dust, etc.).
Units not for operation in combustible dust atmospheres (i.e.
saw dust, flour, etc.).
Humidity / Moisture: Units not for operation outdoors or in conditions where
condensation forms.
Atmosphere: Units not for operation in explosive atmospheres (i.e. natural
gas fumes, oil based paint fumes, etc.).