Specifications
XMU+ Installation and Maintenance Guide rev.07 107
Standard XMU+ Tasks
Standard XMU
+
Tasks
The following standard procedures may be required on their own, or as a part of more
complete upgrade procedures. They should be reviewed thoroughly.
XMU+ maintenance and upgrades should only be completed by a
qualified telecommunications / electronics technician. Standard
static discharge precautions must be followed when handling any
internal components. ESD precautions should also be observed.
Interalia cannot be held responsible for damage to parts or
equipment caused by improper handling or installation.
To take the XMU
+
offline
Take the XMU+ offline before performing maintenance tasks to ensure that callers are
not cut-off abruptly.
1. Press Enter to access the Main Menu.
2. Press the Right Arrow to reach Card on the Main
Menu, and press Enter.
3. Press the Right Arrow button until you reach the
desired card number on the menu, and press Enter.
The display will now show Card # 1 Select Line.
4. Press Enter to select Select Line.
5. Press the Right Arrow button until you reach the ALL
option on the menu, and press Enter. The display will
now show Warning! All lines selected.
6. Press Enter to acknowledge the warning message.
7. Press the Right Arrow button until you reach the
Mode option on the menu, and press Enter twice.
8. Press the Right Arrow button until you reach the
Offline mode, and press Enter.
9. Press Exit until the menu returns to the main display.
ESD
Electrostatic
Discharge