User Manual
  3UG4651 speed monitoring relay 
  13.7 Technical data 
3UG4 / 3RR2 monitoring relays 
Manual, 02/2013, NEB927043002000/RS-AA/002 
305 
13.7  Technical data 
Measuring circuit 
  3UG4651-..... 
Measurable  line  frequency Hz 50 … 60 
Adjustable  response  delay  time   
•  when  starting 
s 
1 … 900 
•  with  lower  or  upper  limit  violation 
s  0.1 … 99.9 
Adjustable  response  value  revolution 1/min 
0.1 … 2 200 
Input  voltage  at  the  digital  input  1   
•  initial  value  for  signal<0>-recognition 
V 
0 
•  final  value  for  signal<0>-recognition 
V  1 
•  initial  value  for  signal<1>-recognition 
V  4.5 
•  final  value  for  signal<1>-recognition 
V  30 
Input  current  at  the  digital  input  2  
•  initial  value  for  signal<0>-recognition 
mA 
0 
•  final  value  for  signal<0>-recognition 
mA  1.2 
•  initial  value  for  signal<1>-recognition 
mA  2.1 
•  final  value  for  signal<1>-recognition 
mA  8.2 
Design  of  the  input  reducing-entrance  
No 
Design  of  the  sensor   
•  at  the  digital  input  1  connectable 
PNP  switching  three-wire  sensor  or 
mechanical  impulse  contact  with 
external  DC  supply  (4.5  V  …  30  V) 
•  at  the  digital  input  2  connectable 
2-conductor  Namur  sensor  or 
mechanical  impulse  contact 
Input  current  at  the  digital  input  1  maximum mA 50 
Pulse  duration  minimum ms 5 
Pulse  interval  minimum ms 5 
Number  of  sensor  signals  per  revolution  1 … 10 
Switching  hysteresis  for  rotational  speed 1/min 0 … 99.9 