Datasheet
Power Relays/Miniature Contactors
3TG10 contactors
4-pole, 4 kW
3/234
Siemens IC 10 · 2011
* You can order this quantity or a multiple thereof.
Illustrations are approximate
3
■
Selection and ordering data
For screw and snap-on mounting onto TH 35 standard mounting rail
■
Accessories
1)
The links for paralleling can be reduced by one pole.
The rated operational currents apply to each pole.
The links for paralleling are insulated.
2)
Replacement for 3TX4 490-2C.
3)
Replacement for 3TX4 490-2A.
4)
Replacement for 3TX4 490-2B.
Rated data
Utilization category
Main
contacts
Rated control
supply
voltage U
s
DT Order No. Price
per PU
PU
(UNIT,
SET,
M)
PS* PG
AC-1
Switching of resistive
loads at 55 °C
AC-2 and AC-3
Opera-
tional
current I
e
up to
400 V
Power of AC
loads at 50 Hz
and 400 V
Opera-
tional
current I
e
up to
400 V
1)
Power of AC
loads at 50 Hz
and 400 V
Version
A kW A kW NO NC V
4-pole ⋅ Hum-free ⋅ With screw terminals
Terminal designations according to EN 50012
1 NO, Ident. No. 10 1 NC, Ident. No. 01E
3TG10 ..-0. . .
AC operation, 45 ... 450 Hz
Screw terminals
20 13 8.4 4 4 -- 24 AC } 3TG10 10-0AC2 1 1 unit 101
110 AC }
3TG10 10-0AG2 1 1 unit 101
230 AC }
3TG10 10-0AL2 1 1 unit 101
3 1 24 AC }
3TG10 01-0AC2 1 1 unit 101
110 AC }
3TG10 01-0AG2 1 1 unit 101
230 AC }
3TG10 01-0AL2 1 1 unit 101
DC operation
20 13 8.4 4 4 -- 24 DC } 3TG10 10-0BB4 1 1 unit 101
3 1 24 DC }
3TG10 01-0BB4 1 1 unit 101
4-pole ⋅ Hum-free ⋅ With flat connectors 6.3 mm x 0.8 mm
Terminal designations according to EN 50012
1 NO, Ident. No. 10 1 NC, Ident. No. 01E
3TG10 ..-1. . .
AC operation, 45 ... 450 Hz
Flat connectors
16 10 8.4 4 4 -- 24 AC } 3TG10 10-1AC2 1 1 unit 101
110 AC D
3TG10 10-1AG2 1 1 unit 101
230 AC }
3TG10 10-1AL2 1 1 unit 101
3 1 24 AC D
3TG10 01-1AC2 1 1 unit 101
110 AC D
3TG10 01-1AG2 1 1 unit 101
230 AC }
3TG10 01-1AL2 1 1 unit 101
DC operation
16 10 8.4 4 4 -- 24 DC C 3TG10 10-1BB4 1 1 unit 101
8.4 4 3 1 24 DC D
3TG10 01-1BB4 1 1 unit 101
Max. rated operational currents I
e
/AC-1
(at 55 °C) of the contactors
Max. conductor
cross-sections
DT Order No. Price
per PU
PU
(UNIT,
SET, M)
PS* PG
Type mm
2
Links for paralleling (star jumpers)
3-pole, without connection terminals
1)
2)
16 star jumpers can be reduced by one pole -- } 3RT19 16-4BA31 11 unit 101
3-pole, with connection terminals
1)3)
40 25 } 3RT19 16-4BB31 11 unit 101
4-pole, with connection terminals
1)4)
40 25 C 3RT19 16-4BB41 11 unit 101
1/L1 13
142/T1
A2(–)
A1(+)
3/L2
4/T2
5/L3
6/T3
1/L1 21
222/T1
A2(–)
A1(+)
3/L2
4/T2
5/L3
6/T3
1/L1 13
142/T1
A2(–)
A1(+)
3/L2
4/T2
5/L3
6/T3
1/L1 21
222/T1
A2(–)
A1(+)
3/L2
4/T2
5/L3
6/T3
IC10_03.book Seite 234 Mittwoch, 15. Dezember 2010 2:20 14
© Siemens AG 2010