10.1 Configuring the IO-Link 
  SIRIUS ACT 3SU1 pushbuttons and signaling devices 
208  System Manual, 02/2015, A5E03457306020A/RS-AB/002 
10.1.3
Configuring with the S7-PCT Stand Alone Port Configuration Tool 
10.1.3.1
Application 
Configuration is always done with the S7-PCT port configuration tool whenever no 
SIMATIC CPU is available. 
10.1.3.2
Basic procedure and prerequisites 
Basic procedure when configuring IO-Link master and IO-Link devices with the S7-PCT Port 
Configuration Tool (stand-alone) 
1.  You configure the connected IO-Link devices with the 
S7-PCT
 Port Configuration Tool. 
Requirements 
●  The 
S7-PCT
 Port Configuration Tool is installed on the PG/PC. 
You can either install 
S7-PCT
 together with STEP 7 V5.4 SP5 or higher or STEP 7 TIA 
Portal V12.0 or higher, or you can download it from the Internet 
(http://support.automation.siemens.com/WW/view/en/37936752). 
●  IO-Link IODD files (IO Device Description) are installed in the 
S7-PCT
 hardware catalog. 
All current IODD files of the SIRIUS devices are available on the Internet 
(https://support.industry.siemens.com/cs/#products?search=IODD&o=DefaultRankingDes
c&lc=en-WW). 
IODD files for V1.0 and V1.1 are available for the combination of an IO-Link master and 
an IO-Link device according to the IO-Link communication specification V1.1. You may 
need IODD files according to the communication specification V1.0 when replacing 
devices in existing installations. 
Note 
Configuring with S7-PCT stand-alone is not possible for the CPU versions of the ET 200. 