Datasheet
● acc. to IEC 60068-2-27
Sinusoidal half-wave 50 g / 11 ms
Vibration resistance
● acc. to IEC 60068-2-6
10 ... 500 Hz: 5g
Surge voltage resistance Rated value 6kV
Mechanical service life (switching cycles)
● typical
10
Equipment marking
● acc. to DIN EN 61346-2
U
● acc. to DIN EN 81346-2
U
Auxiliary circuit:
Number of NC contacts
● for auxiliary contacts
0
Number of NO contacts
● for auxiliary contacts
0
Number of CO contacts
● for auxiliary contacts
0
Connections/ Terminals:
Tightening torque
● for grounding
0.8...1N·m
Ambient conditions:
Ambient temperature
● during operation
-25...+70°C
● during storage
-40...+80°C
Installation/ mounting/ dimensions:
Mounting type
● of modules and accessories
Front plate mounting
Height 40mm
Width 30mm
Shape of the installation opening round
Certificates/ approvals:
Further information