User Manual
3SU12 compact units   
6.1 Overview 
  SIRIUS ACT 3SU1 pushbuttons and signaling devices 
128  System Manual, 02/2015, A5E03457306020A/RS-AB/002 
Procedure (example of mounting on front plate) 
1.  Insert the sensor switch into an enclosure (e.g. 3SU18..-3 two-hand operation console) or 
front plate 
①. 
2.  Align the sensor switch so that it is positioned correctly (LED). 
3.  Place the holder 
② from behind onto the sensor switch and lock it in position. 
4.  Turn the screw 
③ at the holder until the sensor switch is fixed securely and cannot 
vibrate or twist (tightening torque 1.0 to 1.2 Nm). 
5.  Connect the sensor switch to a controller using a connector (3SU1900-0KL10-0AA0). 