Datasheet

Equipment marking
● acc. to DIN EN 61346-2
P
● acc. to DIN EN 81346-2
P
Operating voltage 1
● with AC
— at 50 Hz Rated value
24V
— at 60 Hz Rated value
24V
● for DC Rated value
24V
Relative positive tolerance of the operating voltage 20%
Relative negative tolerance of the operating voltage 20%
Connections/ Terminals:
Type of electrical connection spring-loaded terminals
Type of connectable conductor cross-section
● solid without core end processing
2x (0.25 ... 1.5 mm²)
● finely stranded with core end processing
2x (0.25 ... 0.75 mm²)
● finely stranded without core end processing
2x (0.25 ... 1.5 mm²)
● for AWG conductors
2x (24 ... 16)
Lamp:
Type of light source LED
Color of the light source green
Ambient conditions:
Ambient temperature
● during operation
-25...+70°C
● during storage
-40...+80°C
Installation/ mounting/ dimensions:
Mounting type
● of modules and accessories
Front plate mounting
Height 36mm
Width 9.8mm
Depth 29.4mm
Certificates/ approvals:
Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
http://www.siemens.com/industrial-controls/catalogs
Industry Mall (Online ordering system)
http://www.siemens.com/industrymall
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3SU14011BB403AA0
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3SU14011BB403AA0
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3SU14011BB403AA0&lang=en
3SU1401-1BB40-3AA0 Changes preserved
Page 2/
3
28.04.2015 © Copyright Siemens AG