Datasheet

● for railway applications acc. to DIN EN 61373
Category 1, Class B
Operating frequency maximum 36001/h
Mechanical service life (switching cycles)
● typical
10000000
Electrical endurance (switching cycles)
● typical
10000000
Thermal current 10A
Equipment marking
● acc. to DIN EN 61346-2
S
● acc. to DIN EN 81346-2
S
Continuous current of the C characteristic MCB 10A
Main circuit
Operating voltage
● at AC
— at 50 Hz rated value
5...500V
— at 60 Hz rated value
5...500V
● at DC
— rated value
5...500V
Power Electronics
Contact reliability One maloperation per 100 million (17 V, 5 mA), one maloperation
per 10 million (5 V, 1 mA)
Auxiliary circuit
Design of the contact of auxiliary contacts Silver alloy
Number of NC contacts
● for auxiliary contacts
1
— lagging switching
0
Number of NO contacts
● for auxiliary contacts
0
— leading contact
0
Number of CO contacts
● for auxiliary contacts
0
Operating current at AC-12
● at 24 V rated value
10A
● at 48 V rated value
10A
● at 110 V rated value
10A
● at 230 V rated value
8A
● at 400 V rated value
8A
Operating current at AC-15
● at 24 V rated value
6A
● at 48 V rated value
6A
● at 110 V rated value
6A
3SU1400-2AA10-3CA0 Subject to change without notice
Page 2/
5
02/09/2017 © Copyright Siemens AG