User Manual
IO-Link   
10.2 Design of a command point with ID key-operated switch 
  SIRIUS ACT 3SU1 pushbuttons and signaling devices 
220  System Manual, 02/2015, A5E03457306020A/RS-AB/002 
10.2.3.6
"Switch position delay" parameter 
Switch position delay  
The switch position delay specifies how long a temporary key position is displayed at the ID 
key-operated switch (by green flashing of the LED on the electronic module for ID key-
operated switches). During this time, it is still possible to change the temporary key position 
by turning the knob. The switch position delay restarts when turning of the rotary knob is 
detected. During the switch position delay, the values at the outputs are not changed. When 
the switch position delay has expired, the temporary key position is accepted as the current 
key position. The status of the outputs is changed in accordance with this position. 
Settings 
Description 
Default setting 
0 
Switch position delay: disabled 
— 
1  Switch position delay: Minimum value  20 (2 seconds) 
100 
Switch position delay: Maximum value 
— 
Increment: 0.1 seconds 
10.2.3.7
"Select memory range" parameter 
"Select memory range" parameter  
The Port Configuration Tool 
S7-PCT 
includes a dropdown menu with which you can select 
the part of the data set to be displayed. The memory range in which the individually 
encodable ID keys are saved can be selected and displayed. 
Settings 
Description 
Default setting 
1  Select memory range: Minimum value  1 (individually encodable key 
1 ... 10) 
5 
Select memory range: Maximum value 
— 
Increment: 10 keys 