User Manual
SIRIUS ACT 3SU1 pushbuttons and signaling devices 
System Manual, 02/2015, A5E03457306020A/RS-AB/002 
205 
  IO-Link 
10 
10.1
Configuring the IO-Link 
10.1.1
Combinations 
IO-Link master and IO-Link device combinations are shown in the following table. 
IO-Link master... 
IO-Link device... 
... according to IO-Link communication 
specification V1.0 
... according to IO-Link communication 
specification V1.1 
...according to IO-Link commu-
nication specification V1.0
Operation according to specification V1.0  Operation according to specification V1.0 
...according to IO-Link commu-
nication specification V1.1 
Operation according to specification V1.0 
Operation according to specification V1.1
1)
1)
  By selection of IODD V1.0.1, the device can be operated according to IO-Link communication specification V1.0. 
Differences between IO-Link communication specifications V1.0 and V1.1 
●  Usable IO-Link message frame length (not relevant) 
●  Application-specific name: V1.0: 64 bytes max./V1.1: 32 bytes max. 
●  IO-Link device LED: V1.0: green/V1.1: Green blinking 
●  Parameter server functionality: V1.0: not available/V1.1: available 