Datasheet
Environmental category during operation acc. to IEC
60721
3M6, 3S2, 3B2, 3C3, 3K6 (with relative air humidity of 10 ... 95 %,
no condensation in operation permitted for all devices behind front
panel)
Installation/ mounting/ dimensions
● (mounting type)
front mounting
● Mounting type of modules and accessories
Front plate mounting
(height) 40mm
Width 30mm
Shape of the installation opening round
Mounting diameter 22.3mm
Positive tolerance of installation diameter 0.4mm
Mounting height 46.4mm
Installation width 75mm
Installation depth 48.6mm
Accessories
Number of backing plates 1
Marking of backing plate EMERGENCY-STOP
Color of backing plate Yellow
Certificates/approvals
General Product Approval Declaration of Conformity
Miscellaneous
Test Certific-
ates
Marine / Shipping
Type Test Certific-
ates/Test Report
Marine / Ship-
ping
other
Confirmation
Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
http://www.siemens.com/industrial-controls/catalogs
3SU1150-1HB20-1CH0 Subject to change without notice
Page 4/
6