AS-Interface   
9.5 Mounting 
  SIRIUS ACT 3SU1 pushbuttons and signaling devices 
172  System Manual, 02/2015, A5E03457306020A/RS-AB/002 
Mounting positions of the ASi F slave 
Note 
Mounting position of the AS-Interface slave 
The AS
-i F slave may only be mounted in the enclosure at the slots marked with "3". 
The AS-i F slaves are factory-mounted at mounting position A3. At the customer's request, 
the ASi F slave can also be mounted at the highest mounting position of the actuator. The 
following mounting positions are possible: 
●   Enclosure with 1 command point ⇒ A3 
●  Enclosure with 3 command points ⇒ C3 
●  Enclosure with 4 command points ⇒ D3 
●  Enclosure with 6 command points ⇒ F3 
Note 
Enclosures with 2 command points 
Enclosures with 2 command points cannot be equipped with an ASi F slave.
Mounting positions of the ASi standard slaves (A/B slaves) 
The ASi standard slaves are always mounted at the mounting positions for support 
terminals. These mounting positions are always located between the mounting panels of the 
actuators and can be recognized by the additional rib of the mounting support. 
Note 
Enclosures with one command point 
Enclosures with only one command p
oint cannot be equipped with ASi standard slaves. 
Mounting position of the AS-Interface standard slave as the first slave
Command points in the enclosure 
Mounting position between mounting panels 
2 
A and B 
3  A and B 
B and C 
4  Always A and B 
except when an EMERGENCY STOP is mounted at A  
6  A and B 
B and C 
D and E 
E and F 