User Manual
IO-Link   
10.2 Design of a command point with ID key-operated switch 
  SIRIUS ACT 3SU1 pushbuttons and signaling devices 
218  System Manual, 02/2015, A5E03457306020A/RS-AB/002 
10.2.3.2
"Incremental mode" parameter 
"Incremental mode" parameter  
The "Incremental mode" parameter influences the evaluation of the current key position.  
1) "Incremental mode" disabled: The adjustment method is used. 
●  Key position ≥1: The output corresponding to the current key position is switched on; the 
remaining outputs 0 ... 3 are inactive. 
●  Key position 0: All outputs 0 ... 3 are inactive. 
Example: Key position = 2: Output 0: Off, output 1: On, output 2: Off, output 3: Off 
2) "Incremental mode" enabled: The addition method is used. 
●  Key position ≥1: The outputs with the indices from 0 to the current switch position are 
switched on; the remaining outputs 0 ... 3 are inactive. 
●  Key position 0: All outputs 0 ... 3 are inactive. 
Example: Key position = 2: Output 0: On, output 1: On, output 2: Off, output 3: Off 
Settings 
Description 
Default setting 
0 
Incremental mode: disabled 
Disabled 
1  Incremental mode: enabled  — 
10.2.3.3
"Switch position memory" parameter 
"Switch position memory" parameter 
1) "Switch position memory" disabled:  
●  No ID key detected. The current switch position is changed to 0 immediately after 
removing the ID key, and all active outputs are deactivated. 
2) "Switch position memory" enabled:  
●  No ID key detected. The last current switch position is retained after the ID key has been 
removed, and all active outputs remain in the switched-on state. The authorization level 
of the currently used ID key must correspond to the authorization level of the current 
switch position or higher. 
This value can be changed by: 
●  Using an ID key with suitable authorization level and turning the rotary knob on the 
ID key-operated switch. 
●  Switching off the power supply (if the parameter "Key memory" is disabled). 