User Manual
SIRIUS ACT 3SU1 pushbuttons and signaling devices 
System Manual, 02/2015, A5E03457306020A/RS-AB/002 
275 
  Appendix 
A 
A.1
Process data and data sets 
A.1.1
Electronic module for ID key-operated switches 
A.1.1.1
Structure of the data sets 
Overview of the data sets  
Table A- 1  Data sets - overview 
Data set 
Name 
Access 
Value 
Length 
(bytes) 
Index 
(dec) 
Index 
(hex) 
Subindex 
supported 
0 
0 
Yes 
Parameter Page 1 
r / w 
— 
16 
2 
2 
Yes 
System Command 
w 
— 
1 
3 
3 
Yes 
Data Storage 
r / w 
— 
24 
12 
0C 
No 
Device Access locks 
r / w 
— 
2 
16 
10 
No 
Vendor Name 
r 
Siemens AG 
10 
17  11  No  Vendor Text  r  Internet 
(http://support.automation.siemens.co
m/WW/view/en/29801139/130000) 
64 
18  12  No  Product Name  r  SIRIUS ACT electronic module for 
ID key-operated switch 
55 
19 
13 
No 
Product ID 
r 
3SU1400-1GD10-1AA0 
18 
23 
17 
No 
Firmware Revision 
r 
— 
5 
24 
18 
No 
Application Specific Name 
r / w 
— 
32 
69 
45 
Yes 
Process Data In 
r 
— 
6 
80  50  Yes  Delete individually en-
codable ID key, data set 80 
r / w  —  5 
81  51  Yes  Memory for the individually 
encodable ID keys (1-30) 
data set 81 
r  —  180 
82  52  Yes  Memory for the individually 
encodable ID keys (31-50) 
data set 82 
r  —  120 
92 
5C 
Yes 
Diagnostics - data set 92 
r 
— 
20 
94 
5E 
Yes 
ID keys - data set 94 
r 
— 
22 
131 
83 
Yes 
Parameters - data set 131 
r / w 
— 
20 