User Manual
  IO-Link 
  10.2 Design of a command point with ID key-operated switch 
SIRIUS ACT 3SU1 pushbuttons and signaling devices 
System Manual, 02/2015, A5E03457306020A/RS-AB/002 
225 
"Data storage inhibition" parameter 
"Data Storage Lock" parameter  
With the "Data Storage Lock" parameter, you define whether or not the mechanism for data 
storage is disabled. 
The table below shows the parameter values.  
Table 10- 4  "Data Storage Lock" parameter 
Value 
Description 
Default setting 
0 
Data Storage Lock: enabled 
Enabled 
1  Data Storage Lock: disabled  — 
10.2.4
Process image 
Process image input (PII)  
The process image input contains the most important status information of the electronic 
modules for the ID key-operated switch for IO-Link.  
Table 10- 5  PII - status information  
DI (2 bytes) 
PII 
DI0.0 
1: Ready 
DI0.1  1: Group error 
DI0.2 
Reserved 
DI0.3 
Reserved 
DI0.4 
Reserved 
DI0.5 
Reserved 
DI0.6 
Reserved 
DI0.7 
Reserved 
DI1.0 
1: ID key detected 
DI1.1 
1: Authorization level 
DI1.2 
1: Switch position 