Datasheet

Product component front ring Yes
Design of the front ring standard
Material of the front ring plastic
Color of the front ring black
General technical data
Protection class IP IP66, IP67, IP69(IP69K)
Degree of protection NEMA rating NEMA 1, 2, 3, 3R, 4, 4X, 12, 13
Shock resistance
● acc. to IEC 60068-2-27
Sinusoidal half-wave 50 g / 11 ms
● for railway applications acc. to DIN EN 61373
Category 1, Class B
Operating frequency maximum 18001/h
Mechanical service life (switching cycles)
● typical
1000000
Reference code acc. to DIN EN 81346-2 S
Reference code acc. to DIN EN 61346-2 S
Safety related data
B10 value
● with high demand rate acc. to SN 31920
100000
Proportion of dangerous failures
● with low demand rate acc. to SN 31920
20%
● with high demand rate acc. to SN 31920
20%
Failure rate [FIT]
● with low demand rate acc. to SN 31920
100FIT
T1 value for proof test interval or service life acc. to
IEC 61508
20y
Ambient conditions
Ambient temperature
● during operation
-25...+70°C
● during storage
-40...+80°C
Environmental category during operation acc. to IEC
60721
3M6, 3S2, 3B2, 3C3, 3K6 (with relative air humidity of 10 ... 95 %)
Installation/ mounting/ dimensions
(height) 32.3mm
Width 32.3mm
Shape of the installation opening round
Mounting diameter 22.3mm
Positive tolerance of installation diameter 0.4mm
Mounting height 28.8mm
Installation width 32.3mm
Installation depth 25.4mm
Certificates/approvals
3SU1002-2BF30-0AA0 Subject to change without notice
Page 2/
4
06/06/2019 © Copyright Siemens