Datasheet
Product component front ring Yes
Design of the front ring Standard
Material of the front ring plastic
Color of the front ring black
General technical data
Protection class IP IP66, IP67, IP69(IP69K)
● of the terminal
IP20
Degree of protection NEMA rating NEMA 1, 2, 3, 3R, 4, 4X, 12, 13
Shock resistance
● acc. to IEC 60068-2-27
Sinusoidal half-wave 50 g / 11 ms
● for railway applications acc. to DIN EN 61373
Category 1, Class B
Operating frequency maximum 18001/h
Mechanical service life (switching cycles)
● typical
1000000
Reference code acc. to DIN EN 81346-2 S
Reference code acc. to DIN EN 61346-2 S
Ambient conditions
Ambient temperature
● during operation
-25...+70°C
● during storage
-40...+80°C
Environmental category during operation acc. to IEC
60721
3M6, 3S2, 3B2, 3C3, 3K6 (with relative air humidity of 10 ... 95 %)
Installation/ mounting/ dimensions
(height) 29.5mm
Width 29.5mm
Shape of the installation opening round
(mounting diameter) 22.3mm
Positive tolerance of installation diameter 0.4mm
Mounting height 61mm
Installation width 29.5mm
Installation depth 25.4mm
Certificates/approvals
3SU1000-5HF11-0AA0 Subject to change without notice
Page 2/
4
06/04/2019 © Copyright Siemens