4.2 Overview
SIRIUS ACT 3SU1 pushbuttons and signaling devices
System Manual, 02/2015, A5E03457306020A/RS-AB/002
65
Typical diagram
Each pressure plate can be individually removed and reinstalled. A pressure plate always
actuates the contact modules mounted on the holder at position 3/6 (center position), and
the corresponding outer contact modules at position 1/4 or 2/5.
If a pressure plate is not used, only the corresponding outer contact at position 1/4 or 2/5 is
actuated.
Note about installation of LED modules: The pressure plates must be removed before the
LED module is installed.
For further information refer to Chapter "Installation (Page 89)"
The table shows the contact module / LED module actuation with differently mounted
pressure plates using the example of a selector switch with 3 switch positions and equipped
contact modules and LED modules.
Switch position left
Switch position right
Pressure plate
①
Contact module
Position 1/4
Contact / LED
module
Position 3/6
Contact module
Position 2/5
Contact module
Position 1/4
Contact / LED
module
Position 3/6
Contact module
Position 2/5
2 pressure
plates mounted
1 pressure
plate mounted
on the right
1 pressure
plate mounted
on the left
No pressure
plate mounted