User Manual
IO-Link
10.2 Design of a command point with ID key-operated switch
SIRIUS ACT 3SU1 pushbuttons and signaling devices
218 System Manual, 02/2015, A5E03457306020A/RS-AB/002
10.2.3.2
"Incremental mode" parameter
"Incremental mode" parameter
The "Incremental mode" parameter influences the evaluation of the current key position.
1) "Incremental mode" disabled: The adjustment method is used.
● Key position ≥1: The output corresponding to the current key position is switched on; the
remaining outputs 0 ... 3 are inactive.
● Key position 0: All outputs 0 ... 3 are inactive.
Example: Key position = 2: Output 0: Off, output 1: On, output 2: Off, output 3: Off
2) "Incremental mode" enabled: The addition method is used.
● Key position ≥1: The outputs with the indices from 0 to the current switch position are
switched on; the remaining outputs 0 ... 3 are inactive.
● Key position 0: All outputs 0 ... 3 are inactive.
Example: Key position = 2: Output 0: On, output 1: On, output 2: Off, output 3: Off
Settings
Description
Default setting
0
Incremental mode: disabled
Disabled
1 Incremental mode: enabled —
10.2.3.3
"Switch position memory" parameter
"Switch position memory" parameter
1) "Switch position memory" disabled:
● No ID key detected. The current switch position is changed to 0 immediately after
removing the ID key, and all active outputs are deactivated.
2) "Switch position memory" enabled:
● No ID key detected. The last current switch position is retained after the ID key has been
removed, and all active outputs remain in the switched-on state. The authorization level
of the currently used ID key must correspond to the authorization level of the current
switch position or higher.
This value can be changed by:
● Using an ID key with suitable authorization level and turning the rotary knob on the
ID key-operated switch.
● Switching off the power supply (if the parameter "Key memory" is disabled).