Data Sheet

Surge voltage resistance rated value 4kV
Protection class IP IP66/IP67
Shock resistance 30g / 11 ms
● acc. to IEC 60068-2-27
30 g / 11 ms
Mechanical service life (switching cycles)
● typical
1000000
Electrical endurance (switching cycles) with contactor
3RH11, 3RT1016, 3RT1017, 3RT1024, 3RT1025,
3RT1026 typical
1000000
Electrical operating cycles in one hour with contactor
3RH11, 3RT1016, 3RT1017, 3RT1024, 3RT1025,
3RT1026
6000
Thermal current 10A
Material of the enclosure of the switch head metal
Reference code acc. to DIN EN 81346-2 B
Reference code acc. to DIN EN 61346-2 B
Continuous current of the C characteristic MCB 1A; for a short-circuit current smaller than 400 A
Continuous current of the quick DIAZED fuse link 10A; for a short-circuit current smaller than 400 A
Continuous current of the DIAZED fuse link gG 6A; for a short-circuit current smaller than 400 A
Locking force 2600N
● acc. to DIN EN ISO 14119
2000N
Repeat accuracy 0.05mm
Minimum actuating force in activation direction 30N
Length of the sensor 185mm
Width of the sensor 54mm
Number of CO contacts for auxiliary contacts 2
Operating current at AC-15
● at 24 V rated value
6A
● at 240 V rated value
3A
Operating current at DC-13
● at 24 V rated value
3A
● at 125 V rated value
0.55A
● at 250 V rated value
0.27A
Design of the interface for safety-related
communication
without
Enclosure
Design of the housing special design
Material of the enclosure metal
Coating of the enclosure cathodic immersion coating
Design of the housing acc. to standard No
Drive Head
Design of the operating mechanism 5 directions of approach
Design of the switching function positive opening
3SE5312-0SD11 Subject to change without notice
Page 2/
7
09/12/2019 © Copyright Siemens