Data Sheet

● at AC-15 at 230 V typical
100000
Electrical operating cycles in one hour with contactor
3RH11, 3RT1016, 3RT1017, 3RT1024, 3RT1025,
3RT1026
6000
Thermal current 4A
Material of the enclosure of the switch head plastic
Reference code acc. to DIN EN 81346-2 B
Reference code acc. to DIN EN 61346-2 B
Continuous current of the C characteristic MCB 1A; for a short-circuit current smaller than 400 A
Continuous current of the quick DIAZED fuse link 4A; for a short-circuit current smaller than 400 A
Continuous current of the DIAZED fuse link gG 4A
Active principle mechanical
Repeat accuracy 0.05mm
Minimum actuating torque in activation direction 0.25N·m
Length of the sensor 224.3mm
Width of the sensor 31mm
Design of the switching contact mechanical
Operating frequency rated value 50...60Hz
Number of NC contacts for auxiliary contacts 1
Number of NO contacts for auxiliary contacts 1
Number of CO contacts for auxiliary contacts 1
Operating current at AC-15
● at 24 V rated value
4A
● at 125 V rated value
4A
● at 240 V rated value
4A
Operating current at DC-13
● at 24 V rated value
3A
● at 125 V rated value
0.55A
● at 250 V rated value
0.27A
Design of the interface for safety-related
communication
without
Enclosure
Design of the housing block, narrow
Material of the enclosure plastic
Coating of the enclosure Other types
Design of the housing acc. to standard Yes
Drive Head
Design of the operating mechanism Spring rod, compl. Length = 142.5 mm (spring 50 mm + plastic
plunger 50 mm)
Standard-compliant actuator head EN 50047
Circuit principle snap-action contacts
Number of switching contacts safety-related 0
3SE5234-0HR01-1AC4 Subject to change without notice
Page 2/
7
09/12/2019 © Copyright Siemens