Datasheet
• of the quick DIAZED fuse link A 10
• of the C characteristic circuit breaker A 1
Mechanical operating cycles as operating time
• typical 15,000,000
Electrical operating cycles as operating time
• with contactor 3RH11, 3RT1016, 3RT1017, 3RT1024, 3RT1025,
3RT1026 / typical
10,000,000
• at AC-15 / at 230 V / typical 100,000
Electrical operating cycles in one hour
• with contactor 3RH11, 3RT1016, 3RT1017, 3RT1024, 3RT1025,
3RT1026
6,000
Repeat accuracy mm 0.05
Design of the contact element snap-action contacts
Number of NC contacts
• for auxiliary contacts 1
Design of the switching function Positive opening with appropriate positive opening
actuator head
Number of NO contacts
• for auxiliary contacts 1
Resistance against vibration 0.35 mm / 5g
Resistance against shock 30g / 11 ms
Ambient temperature
• during operating °C -25 … +85
• during storage °C -40 … +90
Width of the sensor mm 56
material
• of the housing metal
Actuating speed mm/s / m/s 0.1 … 2.5
Minimum actuating force / in activation direction N 20
Protection class IP IP66/IP67
Built in orientation any
Cable gland version 3 x (M20 x 1.5)
Design of the electrical connection screw-type terminals
Item designation
• according to DIN 40719 extendable after IEC 204-2 S
• according to DIN EN 61346-2 B
Certificates/approvals:
3SE5122-0CA00
Page 2/ 03/30/2012
subject to modifications
© Copyright Siemens AG 2012
3