• at 40 °C / rated value A 12.5
• at 50 °C / rated value A 11
• at 60 °C / rated value A 10
Emitted mechanical power / for three-phase servomotors
• at 230 V / at standard switching / at 40 °C
• rated value W 3,000
• at 400 V / at standard switching / at 40 °C
• rated value W 5,500
yielded mechanical performance (hp) / for three-phase squirrel
cage motors / at 200/208 V / at standard circuit / at 50 °C / rated
v
alue
hp 3
Operating frequency
• rated value Hz 50 … 60
Relative negative tolerance / of the operating frequency % -10
Relative positive tolerance / of the operating frequency % 10
Operating voltage / with standard circuit / rated value V 200 … 480
Relative negative tolerance / of the operating voltage / with
standard circuit
% -15
Relative positive tolerance / of the operating voltage / with
standard circuit
% 10
Minimum load in % of l_M % 20
Adjustable rated current / of the motor / for motor overload
protection / minimum
A 5
Continuous operating current in % of l_e / at 40°C % 115
Active power loss / at operating current / at 40°C / during
operating phase / typical
W 2
Control electronics:
Type of voltage / of the controlled supply voltage AC/DC
Control supply voltage frequency / 1 / rated value Hz 50
Control supply voltage frequency / 2 / rated value Hz 60
Relative negative tolerance / of the control supply voltage
frequency
% -10
Relative positive tolerance / of the control supply voltage
frequency
% 10
Control supply voltage / 1
• at 50 Hz / for AC V 24
• at 60 Hz / for AC V 24
Relative negative tolerance / of the control supply voltage / at 60
Hz / for AC
% -20
Relative positive tolerance / of the control supply voltage / at 60
Hz / for AC
% 20
Control supply voltage / 1 / for DC / rated value V 24