Data Sheet
● at DC
15...24V
Control supply voltage
● at DC / initial value for signal <1> detection
15V
● at DC / Full-scale value for signal<0>
recognition
5V
Switch-on delay time 1ms; additionally max. one half-wave
Off-delay time 1ms; additionally max. one half-wave
Installation/ mounting/ dimensions
Height 100mm
Width 22.5mm
Depth 91mm; 94.0 mm up to product revision E05
Electromagnetic compatibility
Conducted interference
● due to burst / acc. to IEC 61000-4-4
2 kV / 5 kHz behavior criterion 2
● due to conductor-earth surge / acc. to IEC
61000-4-5
2 kV behavior criterion 2
● due to conductor-conductor surge / acc. to IEC
61000-4-5
1 kV behavior criterion 2
● due to high-frequency radiation / acc. to IEC
61000-4-6
140 dBuV in the frequency range 0.15 ... 80 MHz, behavior
criterion 1
Electrostatic discharge / acc. to IEC 61000-4-2 4 kV contact discharging / 8 kV air discharging, behavior criterion
2
Conducted HF-interference emissions / acc. to
CISPR11
Class A for industrial environment
Field-bound HF-interference emission / acc. to
CISPR11
Class B for the domestic, business and commercial environments
Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
www.siemens.com/sirius/catalogs
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RF2310-1AA04-0KN0
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RF2310-1AA04-0KN0
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3RF2310-1AA04-0KN0
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RF2310-1AA04-0KN0&lang=en
Short-circuit protection, design of the fuse link
https://www.automation.siemens.com/cd-static/material/info/3RF20_eng.pdf
Short-circuit protection, design of the fuse link
https://www.automation.siemens.com/cd-static/material/info/3RF21_eng.pdf
Short-circuit protection, design of the fuse link
https://www.automation.siemens.com/cd-static/material/info/3RF22_eng.pdf
Short-circuit protection, design of the fuse link
https://www.automation.siemens.com/cd-static/material/info/3RF23_eng.pdf
Short-circuit protection, design of the fuse link
https://www.automation.siemens.com/cd-static/material/info/3RF24_eng.pdf
3RF2310-1AA04-0KN0 Subject to change without notice
Page 2/
5
09/13/2019 © Copyright Siemens