Brochure
Table Of Contents
- Table of Contents/TIs
- Pneumatic Room Thermostats-Powerstar
- Pneumatic Room Thermostats- D Series
- Pneumatic Thermostats for Specialized Applications
- Pneumatic Relative Humidity Sensors
- Electric Room Thermostats/Controllers
- Low Voltage Wall Thermostats
- Line Voltage Remote Bulb Thermostats
- Line Voltage Room Thermostats-Heating/Cooling
- RAA... Room Thermostats
- RAB... Fan Coil Thermostats
- RCC... Room Temperature Controllers for 2-pipe Fan Coil Units
- RCC... Free Energy Band Room Temperature Controllers for 4-pipe Fan Coil Units
- RCU50... Room Temperature Controllers for CAV and VAV Systems
- RCU61 Room Temperature Controllers for CAV and VAV Systems
- RDU... Room Temperature Controllers with LCD for Heating/Cooling Systems
- RDX... Room Temperature Controllers with LCD
- Electric Thermostats for Specialized Applications
- Accessories and Service Kits
features
A-7
www.sbt.siemens.com/hvp/components
Description
Applications
Thermostats & Hygrostats
192 HC
Powerstar Heating/Cooling
Pneumatic Room Thermostats
Typical wall plate and screws.192 HC Thermostat
chassis.
192 HC Thermostat with plastic cover. Chassis wall plate with
easy maintenance plug-in adapters shown (optional).
Designed for temperature control of heating and cooling
applications, the 192 HC Powerstar Heating/Cooling Pneu-
matic Room Thermostat controls valves and damper actua-
tors in cooling equipment. Providing energy management
and occupant comfort, the thermostat automatically adjusts
to seasonal changes from heating set point to cooling set
point in commercial and institutional facilities.
Recommendation
For control of multiple valves and actuators, use with or
without high/low limiting controls.
Providing proportional single output, dual set point with
2-pipe for high air capacity pneumatic room temperature
control, the 192 HC Powerstar Heating/Cooling Pneu-
matic Room Thermostat provides two thermostats under
one cover; one side for heating and the other for cooling.
Switchover is accomplished by changing the air pressure to
the thermostat.
• Dual set point dial available in Fahrenheit
or Celsius scales
• Available in direct or reverse acting models
• Sensitive bimetal responds to temperature
changes
• Integral, field adjustable limit stops
• Adjustable changeover pressure
• Large volume air capacity relay
• Wall mounting plates provides connection
to a variety of rough-in terminal boxes
• Test port for fast check of output pressure
without removing the cover
• Field replaceable thermometer, set point
dials, restrictor and filters
Options
• Fixed limit stops to meet government
specifications
• Quick-connect air connections for ease of
installation and service
• Large, 1/2” set point knob for convalescent
homes
Application Drawing