Brochure
Table Of Contents
- Table of Contents/TIs
- Pneumatic Room Thermostats-Powerstar
- Pneumatic Room Thermostats- D Series
- Pneumatic Thermostats for Specialized Applications
- Pneumatic Relative Humidity Sensors
- Electric Room Thermostats/Controllers
- Low Voltage Wall Thermostats
- Line Voltage Remote Bulb Thermostats
- Line Voltage Room Thermostats-Heating/Cooling
- RAA... Room Thermostats
- RAB... Fan Coil Thermostats
- RCC... Room Temperature Controllers for 2-pipe Fan Coil Units
- RCC... Free Energy Band Room Temperature Controllers for 4-pipe Fan Coil Units
- RCU50... Room Temperature Controllers for CAV and VAV Systems
- RCU61 Room Temperature Controllers for CAV and VAV Systems
- RDU... Room Temperature Controllers with LCD for Heating/Cooling Systems
- RDX... Room Temperature Controllers with LCD
- Electric Thermostats for Specialized Applications
- Accessories and Service Kits
A-14
Specifications/Product Ordering
Thermostats & Hygrostats
Scale; Range
Major (minor) Divisions ........................................... 45 to 85°F, 10(2)°F/
(7 to 30°C, 5(1)°C)
Factory Calibration
“FEB” Output Pressure .................................................. 7.5 psi (52 kPa)
Temperature ........................................................................ 72°F (22°C)
Sensitivity .............................................................2.5 psi/°F (31 kPa/°C)
Sensitivity Adjustment Range ............................................. 1 to 4 psi/°F
(12 to 50 kPa/°C)
Limit Stop, Field Adjustment Range ......................... 55/75°F (13/24°C)
Temperature
Storage ......................................................-10 to +140°F (-23 to +60°C)
Ambient Operating .......................................... 40 to 140°F (4 to 60°C)
Accuracy at Factory
Calibration ........................................................................ ±2°F (±1.1°C)
Response ........................................................................ 0.1°F (0.06°C)
Supply Air Pressure
Recommended ........................................................... 25 psig (172 kPa)
Maximum .................................................................... 30 psig (207 kPa)
Free Energy Band
Output Pressure Adjustment ........................ 1 to 15 psig (7 to 103 kPa)
Range .................................................................... 0 to 40°F (0 to 20°C)
Nominal Air Capacity for Compressor Sizing ............ 40 scim (11 ml/s)
Nominal Air Capacity for Air Main Sizing ................... 40 scim (11 ml/s)
Nominal Chassis Air Capacity
Supply ....................................................................... 150 scim (41 ml/s)
Exhaust ..................................................................... 150 scim (41 ml/s)
Supply/2-pipe Exhaust ................................ 150 scim (41 ml/s) per side
Air Connections ..................................................5/32” (4 mm) OD tubing
Dimensions (with cover) ..............................2.16” W x 3.34” H x 1.59” D
(55 mm W x 85 mm H x 40 mm D)
Shipping Weights
Thermostat Chassis and Wall Plate ............................ 0.53 lb. (0.24 kg)
Plastic Cover .............................................................. 0.07 lb. (0.04 kg)
Metal Cover (dual) ....................................................... 0.27 lb. (0.12 kg)
Code Color (add suffix to Part No.)
None Desert Beige (standard)
W White
METAL COLORS
Code Color (add suffix to part No.)
A #1 Silver
B #5 Satin Chrome
C #7 Light Statuary Bronze
D #10 Special Bronze
E
Brushed Electroplated Satin Chrome
F Sierra Gold
G Brushed Aluminum
H White
Cover Options
PLASTIC COLORS
Code Description (add suffix to Part No.)
K Chassis with 1/2” (13 mm)
diameter set point adjustment
knob for convalescent facilities.
For Horizontal Cover, refer to the
Accessories and Service Kits section.
Chassis Options
For Color Chip Samples,
order 152-178P10.
Thermostat Chassis
Model # Thermostat Chassis Type & Wall Plate
Air Output Thermometer &
Output Set Point Capacity Set Point Scales Control Action
Heat (DA/ Heat (RA)/
Cool (DA) Cool (RA)
Single Dual High °F 193-219 193-220
(Heat and Cool) (Integral Relay) °C 193-239 193-240
193 HC
Hesitation
Cover Description Plastic Metal
• Adjustment set point concealed 192-257 192-357
• Indicator set point concealed
• Chassis thermometer concealed
• No logo
• Adjustment set point concealed 192-256 192-356
• Indicator set point concealed
• Chassis thermometer concealed
• Logo
• Adjustment set point concealed 192-254 192-354
• Indicator set point concealed
• Chassis thermometer exposed
• Adjustment set point key 192-267 192-367
• Indicator set point exposed
• Chassis thermometer concealed
• Use with 1/2” set point knob option
• Adjustment set point key 192-268 192-368
• Indicator set point exposed
• Chassis thermometer exposed
• Use with 1/2” set point knob option
• Adjustment set point exposed
• Indicator set point exposed 192-258 192-358
• Chassis thermometer concealed
• Adjustment set point exposed 192-260 192-360
• Indicator set point exposed
• Chassis thermometer exposed
Ordering Note
• “Exposed features” are indicated in green on corresponding illustration.
Options
Color
193 HC
Thermostat Covers
Thermostat Covers
Sold Separately
Page
76
Page
76