User Manual
Table Of Contents
- 1 Cyber security disclaimer
- 2 Preconditions of this document
- 3 System overview
- 4 Desigo workflow, tools and programming
- 4.1 Coverage of the technical process
- 4.2 Coverage of the system
- 4.3 Main tasks
- 4.4 Tools for different roles
- 4.5 Working with libraries
- 4.6 Working in parallel and subcontracting
- 4.7 Workflow for primary systems
- 4.8 Workflow for room automation classic
- 4.9 Workflow for Desigo room automation
- 4.10 Desigo Configuration Module (DCM)
- 4.11 Desigo Xworks Plus (XWP)
- 4.12 Desigo Automation Building Tool (ABT)
- 4.13 Programming in D-MAP
- 5 Control concept
- 6 Technical view
- 7 Global objects and functions
- 8 Events and COV reporting
- 9 Alarm management
- 9.1 Alarm sources
- 9.2 Alarm example
- 9.3 Effects of BACnet properties on alarm response
- 9.4 Alarm response of the function blocks
- 9.5 Alarm functions
- 9.6 Alarm management by notification class
- 9.7 Alarm routing over the network
- 9.8 Alarm queuing
- 9.9 Common alarms
- 9.10 Alarm suppression
- 9.11 Alarm message texts
- 10 Calendars and schedulers
- 11 Trending
- 12 Reports
- 13 Data storage
- 14 Network architecture
- 15 Remote access
- 16 Management platform
- 17 Desigo Control Point
- 18 Automation stations
- 19 Logical I/O blocks
- 20 Room automation
- 21 Desigo Open
- 22 System configuration
- 22.1 Technical limits and limit values
- 22.2 Maximum number of elements in a network area
- 22.3 Desigo room automation system function group limits
- 22.4 Devices
- 22.4.1 PXC..D automation stations / system controllers
- 22.4.2 LonWorks system controllers
- 22.4.3 Automation stations with LonWorks integration
- 22.4.4 PX Open integration (PXC001.D/-E.D)
- 22.4.5 PX Open integration (PXC001.D/-E.D + PXA40-RS1)
- 22.4.6 PX Open integration (PXC001.D/-E.D + PXA40-RS2)
- 22.4.7 PX KNX integration (PXC001.D/-E.D)
- 22.4.8 TX Open integration (TXI1/2/2-S.OPEN)
- 22.4.9 Number of data points on Desigo room automation stations
- 22.4.10 Number of data points for PXC3
- 22.4.11 Number of data points for DXR1
- 22.4.12 Number of data points for DXR2
- 22.4.13 PXM20 operator unit
- 22.4.14 PXM10 operator unit
- 22.4.15 Desigo Control Point
- 22.4.16 PXG3.L and PXG3.M BACnet routers
- 22.4.17 SX OPC
- 22.4.18 Desigo CC
- 22.4.19 Desigo Insight
- 22.4.20 Desigo Xworks Plus (XWP)
- 22.4.21 Desigo Automation Building Tool (ABT)
- 22.5 Applications
- 23 Compatibility
- 23.1 Desigo version compatibility definition
- 23.2 Desigo system compatibility basics
- 23.2.1 Compatibility with BACnet standard
- 23.2.2 Compatibility with operating systems
- 23.2.3 Compatibility with SQL servers
- 23.2.4 Compatibility with Microsoft Office
- 23.2.5 Compatibility with web browsers
- 23.2.6 Compatibility with ABT Go
- 23.2.7 Compatibility with VMware (virtual infrastructure)
- 23.2.8 Compatibility of software/libraries on the same PC
- 23.2.9 Hardware and firmware compatibility
- 23.2.10 Backward compatibility
- 23.2.11 Engineering compatibility
- 23.2.12 Compatibility with Desigo Configuration Module (DCM)
- 23.2.13 Compatibility with Desigo PX / Desigo room automation
- 23.2.14 Compatibility with Desigo RX tool
- 23.2.15 Compatibility with TX-I/O
- 23.2.16 Compatibility with TX Open
- 23.3 Desigo Control Point
- 23.4 Upgrading from Desigo V6.2 Update (or Update 2) to V6.2 Update 3
- 23.5 Siemens WEoF clients
- 23.6 Migration compatibility
- 23.7 Hardware requirements of Desigo software products
- 24 Desigo PXC4 and PXC5
- 25 Compatibility of Desigo V6.2 Update 3 with PXC4 and PXC5
Compatibility
Upgrading from Desigo V6.2 Update (or Update 2) to V6.2 Update 3
23
CM110664en_07 343 | 351
23.4.2.1 Project case 1: Maintenance
Cases where you want to maintain your data and your site/project:
● Edit an existing site/project. Edit an existing site/project without adding automation stations or new
features.
● Extend the site with new devices of the same type, while keeping the same old application version, and
not using new features.
● Replace a defect automation station with a new device of the same kind, where the old application can
be reused, e.g., replace a PX with a PX, a PXC3 with a PXC3, a DXR2 with a DXR2.
The downgrade of automation station firmware is a potential security risk. Doing so is strongly
discouraged.
● Benefit from the latest security releases. Upgrade the firmware of the devices. Keep the applications as
they are.
Prerequisites for upgrading from Desigo V6.2 Update (or Update 2) to V6.2 Update 3
(Offline)
● The XWP V6.2 Update 3 Tool and library and the ABT V4.0 Site/Pro Tool and libraries are installed.
For details, see the release notes for the applicable tool: XWP, ABT Pro, and ABT Site.
● The needed RC local library V6.2 Update is installed.
For details, contact your local Tool Manager.
● You have the project data and the credentials for the project you want to work on.
● The project data conversion from V6.2 to V6.2 Update happens automatically.
– When you open an XWP project, the XWP project is converted automatically.
– When you open an automation station in XWP, the CFC data is converted automatically.
– When you navigate to ABT Site, the conversion is done automatically.
Once XWP data and/or ABT data have been converted, you may not open the project with an old tool
version.
The new TIA15.1 version is included with the ABT V4.0 Tools installation. Conversion is needed.
For details, see
Project Converter Wizard
(CM110633en28_06).
How to upgrade from Desigo V6.2 Update (or Update 2) to V6.2 Update 3 (Online)
1. Upgrade the automation stations firmware to the latest version or replace the automation station with a
new automation station.
– Read back the parameters of the device with the tool, when the device is available for readback.
– Check the availability of the latest firmware per device in the VVS table.
For details about upgrading the automation station firmware, see the documentation of the applicable
tool: XWP, ABT Pro, and ABT Site.
2. Edit the application in the automation station.
For details, see the documentation of the applicable tool: XWP, ABT Pro, and ABT Site.
3. You do not need to upgrade Desigo CC and/or Desigo Control Point.
23.4.2.2 Project case 2: Extension with new features
Cases where you want to use new features for one or several automation stations:
● Extend the site with new devices from the latest version (recently introduced).
● Benefit from new features both on firmware and applications (recently introduced).
● Replace an automation station type with another automation station type, which does not have the
possibility to fully reuse the application program, and needs to be reprogrammed.
Prerequisites for upgrading from Desigo V6.2 Update (or Update 2) to V6.2 Update 3
(Offline)
● The XWP V6.2 Update 3 Tool and library and the ABT V4.0 Site/Pro Tool and libraries are installed.
For details, see the release notes for the applicable tool: XWP, ABT Pro, and ABT Site.
● The needed RC local library V6.2 Update 3 is installed.