User Manual
Table Of Contents
- 1 Cyber security disclaimer
- 2 Preconditions of this document
- 3 System overview
- 4 Desigo workflow, tools and programming
- 4.1 Coverage of the technical process
- 4.2 Coverage of the system
- 4.3 Main tasks
- 4.4 Tools for different roles
- 4.5 Working with libraries
- 4.6 Working in parallel and subcontracting
- 4.7 Workflow for primary systems
- 4.8 Workflow for room automation classic
- 4.9 Workflow for Desigo room automation
- 4.10 Desigo Configuration Module (DCM)
- 4.11 Desigo Xworks Plus (XWP)
- 4.12 Desigo Automation Building Tool (ABT)
- 4.13 Programming in D-MAP
- 5 Control concept
- 6 Technical view
- 7 Global objects and functions
- 8 Events and COV reporting
- 9 Alarm management
- 9.1 Alarm sources
- 9.2 Alarm example
- 9.3 Effects of BACnet properties on alarm response
- 9.4 Alarm response of the function blocks
- 9.5 Alarm functions
- 9.6 Alarm management by notification class
- 9.7 Alarm routing over the network
- 9.8 Alarm queuing
- 9.9 Common alarms
- 9.10 Alarm suppression
- 9.11 Alarm message texts
- 10 Calendars and schedulers
- 11 Trending
- 12 Reports
- 13 Data storage
- 14 Network architecture
- 15 Remote access
- 16 Management platform
- 17 Desigo Control Point
- 18 Automation stations
- 19 Logical I/O blocks
- 20 Room automation
- 21 Desigo Open
- 22 System configuration
- 22.1 Technical limits and limit values
- 22.2 Maximum number of elements in a network area
- 22.3 Desigo room automation system function group limits
- 22.4 Devices
- 22.4.1 PXC..D automation stations / system controllers
- 22.4.2 LonWorks system controllers
- 22.4.3 Automation stations with LonWorks integration
- 22.4.4 PX Open integration (PXC001.D/-E.D)
- 22.4.5 PX Open integration (PXC001.D/-E.D + PXA40-RS1)
- 22.4.6 PX Open integration (PXC001.D/-E.D + PXA40-RS2)
- 22.4.7 PX KNX integration (PXC001.D/-E.D)
- 22.4.8 TX Open integration (TXI1/2/2-S.OPEN)
- 22.4.9 Number of data points on Desigo room automation stations
- 22.4.10 Number of data points for PXC3
- 22.4.11 Number of data points for DXR1
- 22.4.12 Number of data points for DXR2
- 22.4.13 PXM20 operator unit
- 22.4.14 PXM10 operator unit
- 22.4.15 Desigo Control Point
- 22.4.16 PXG3.L and PXG3.M BACnet routers
- 22.4.17 SX OPC
- 22.4.18 Desigo CC
- 22.4.19 Desigo Insight
- 22.4.20 Desigo Xworks Plus (XWP)
- 22.4.21 Desigo Automation Building Tool (ABT)
- 22.5 Applications
- 23 Compatibility
- 23.1 Desigo version compatibility definition
- 23.2 Desigo system compatibility basics
- 23.2.1 Compatibility with BACnet standard
- 23.2.2 Compatibility with operating systems
- 23.2.3 Compatibility with SQL servers
- 23.2.4 Compatibility with Microsoft Office
- 23.2.5 Compatibility with web browsers
- 23.2.6 Compatibility with ABT Go
- 23.2.7 Compatibility with VMware (virtual infrastructure)
- 23.2.8 Compatibility of software/libraries on the same PC
- 23.2.9 Hardware and firmware compatibility
- 23.2.10 Backward compatibility
- 23.2.11 Engineering compatibility
- 23.2.12 Compatibility with Desigo Configuration Module (DCM)
- 23.2.13 Compatibility with Desigo PX / Desigo room automation
- 23.2.14 Compatibility with Desigo RX tool
- 23.2.15 Compatibility with TX-I/O
- 23.2.16 Compatibility with TX Open
- 23.3 Desigo Control Point
- 23.4 Upgrading from Desigo V6.2 Update (or Update 2) to V6.2 Update 3
- 23.5 Siemens WEoF clients
- 23.6 Migration compatibility
- 23.7 Hardware requirements of Desigo software products
- 24 Desigo PXC4 and PXC5
- 25 Compatibility of Desigo V6.2 Update 3 with PXC4 and PXC5
System configuration
Devices
22
326 | 351 CM110664en_07
ASN Max. number of data points Description
DXR1.E02PLZ-
112
2 n/a
DXR1.M04PDZ-
112
n/a 2 UI
DXR1.M09PDZ-
112
16 2 UI, 4 DO, 1 AO
DXR1.M09PDZ-
113
16 2 UI, 4 DO, 1 AO
Key
a1
Total Number of PL-Link data points (under unconfigured status): 36
a2
Activate all selectable PL-Link devices, then check the maximum number of PL-Link data points: 12
b1
Total Number of PL-Link data points (under unconfigured status): 28
b2
Activate all selectable PL-Link devices, then check the maximum number of PL-Link data points: 9
22.4.12 Number of data points for DXR2
ASN Max. number of onboard IO- and KNX PL-Link data
points
Description
DXR2.x09 30 1 DI, 2 UI, 3 AO, 3 Relay
DXR2.x09T 30 1 DI, 2 UI, 4 Triac, 1 AO, 1 Relay
DXR2.x10 30 1 DI, 2 UI, 4 Triac, 3 Relay
DXR.x10PL 30 1 Pressure, 1 DI, 2 UI, 4 Triac, 1 AO
DXR.x10PLX 60 1 Pressure, 1 DI, 2 UI, 4 Triac, 1 AO
DXR2.x11 30 1 DI, 2 UI, 6 Triac, 2 AO
DXR2.x12P 30 1 Pressure, 1 DI, 2 UI, 6 Triac, 2 AO
DXR2.x12PX 60 1 Pressure, 1 DI, 2 UI, 6 Triac, 2 AO
DXR2.E17C-1 30 3 DI, 2 10K input impedance, 4 UI, 4 Triac, 4 AO
DXR2.E17CX-1 60 3 DI, 2 10K input impedance, 4 UI, 4 Triac, 4 AO
DXR2.x18 60 2 DI, 4 UI, 8 Triac, 4 AO
Web clients for room operation
Item Limit Description
QMX7.E38 and standard web clients
1
3 Recommended number of web clients that can simultaneously
access a DXR2.
Templates with standard background
pictures
2
2 Maximum number of different templates which are using the
default background pictures.
Customized background pictures
2
1.5 MB Maximum total size of all customized background pictures (the
PNG file format is used as a reference).
Key
1
Restriction: When using standard web clients (web browser on PCs, smart phones, tablets, etc.), the screen display and
operation (touch or mouse) are neither modified nor tested for the available browsers.
2
Valid values when using 8 room applications at the boundary of maximum system limits.