User Manual
Table Of Contents
- 1 Cyber security disclaimer
- 2 Preconditions of this document
- 3 System overview
- 4 Desigo workflow, tools and programming
- 4.1 Coverage of the technical process
- 4.2 Coverage of the system
- 4.3 Main tasks
- 4.4 Tools for different roles
- 4.5 Working with libraries
- 4.6 Working in parallel and subcontracting
- 4.7 Workflow for primary systems
- 4.8 Workflow for room automation classic
- 4.9 Workflow for Desigo room automation
- 4.10 Desigo Configuration Module (DCM)
- 4.11 Desigo Xworks Plus (XWP)
- 4.12 Desigo Automation Building Tool (ABT)
- 4.13 Programming in D-MAP
- 5 Control concept
- 6 Technical view
- 7 Global objects and functions
- 8 Events and COV reporting
- 9 Alarm management
- 9.1 Alarm sources
- 9.2 Alarm example
- 9.3 Effects of BACnet properties on alarm response
- 9.4 Alarm response of the function blocks
- 9.5 Alarm functions
- 9.6 Alarm management by notification class
- 9.7 Alarm routing over the network
- 9.8 Alarm queuing
- 9.9 Common alarms
- 9.10 Alarm suppression
- 9.11 Alarm message texts
- 10 Calendars and schedulers
- 11 Trending
- 12 Reports
- 13 Data storage
- 14 Network architecture
- 15 Remote access
- 16 Management platform
- 17 Desigo Control Point
- 18 Automation stations
- 19 Logical I/O blocks
- 20 Room automation
- 21 Desigo Open
- 22 System configuration
- 22.1 Technical limits and limit values
- 22.2 Maximum number of elements in a network area
- 22.3 Desigo room automation system function group limits
- 22.4 Devices
- 22.4.1 PXC..D automation stations / system controllers
- 22.4.2 LonWorks system controllers
- 22.4.3 Automation stations with LonWorks integration
- 22.4.4 PX Open integration (PXC001.D/-E.D)
- 22.4.5 PX Open integration (PXC001.D/-E.D + PXA40-RS1)
- 22.4.6 PX Open integration (PXC001.D/-E.D + PXA40-RS2)
- 22.4.7 PX KNX integration (PXC001.D/-E.D)
- 22.4.8 TX Open integration (TXI1/2/2-S.OPEN)
- 22.4.9 Number of data points on Desigo room automation stations
- 22.4.10 Number of data points for PXC3
- 22.4.11 Number of data points for DXR1
- 22.4.12 Number of data points for DXR2
- 22.4.13 PXM20 operator unit
- 22.4.14 PXM10 operator unit
- 22.4.15 Desigo Control Point
- 22.4.16 PXG3.L and PXG3.M BACnet routers
- 22.4.17 SX OPC
- 22.4.18 Desigo CC
- 22.4.19 Desigo Insight
- 22.4.20 Desigo Xworks Plus (XWP)
- 22.4.21 Desigo Automation Building Tool (ABT)
- 22.5 Applications
- 23 Compatibility
- 23.1 Desigo version compatibility definition
- 23.2 Desigo system compatibility basics
- 23.2.1 Compatibility with BACnet standard
- 23.2.2 Compatibility with operating systems
- 23.2.3 Compatibility with SQL servers
- 23.2.4 Compatibility with Microsoft Office
- 23.2.5 Compatibility with web browsers
- 23.2.6 Compatibility with ABT Go
- 23.2.7 Compatibility with VMware (virtual infrastructure)
- 23.2.8 Compatibility of software/libraries on the same PC
- 23.2.9 Hardware and firmware compatibility
- 23.2.10 Backward compatibility
- 23.2.11 Engineering compatibility
- 23.2.12 Compatibility with Desigo Configuration Module (DCM)
- 23.2.13 Compatibility with Desigo PX / Desigo room automation
- 23.2.14 Compatibility with Desigo RX tool
- 23.2.15 Compatibility with TX-I/O
- 23.2.16 Compatibility with TX Open
- 23.3 Desigo Control Point
- 23.4 Upgrading from Desigo V6.2 Update (or Update 2) to V6.2 Update 3
- 23.5 Siemens WEoF clients
- 23.6 Migration compatibility
- 23.7 Hardware requirements of Desigo software products
- 24 Desigo PXC4 and PXC5
- 25 Compatibility of Desigo V6.2 Update 3 with PXC4 and PXC5
Desigo Open
Integration on automation level
21
308 | 351 CM110664en_07
An OPC server option provides a freely configurable set of data points for integration in any enterprise
system, using the OPC DA standard. Each data point (object) is represented by several OPC items,
providing the relevant readable and writable object property information.
See
OPC DA Server Manual
(A6V10415485).
The Desigo CC OPC server is officially tested and certified by the OPC foundation
(https://opcfoundation.org/products/view/251).
OPC UA server
OPC Unified Architecture (OPC UA) clients can connect to the Desigo CC OPC DA server using the OPC
DA/UA wrapper, provided with the Desigo CC setup. The UA wrapper meets the security model of mutual
authentication for a trusted connection between the OPC UA server and the OPC UA client.
See
OPC DA Server Manual
(A6V10415485).
SNMP
Simple Network Management Protocol (SNMP) is a data communication protocol for monitoring devices
and applications on a network. It is an Ethernet based protocol for retrieving management data from
networked devices, and exposing this data as properties.
SNMP gives you the capability to monitor a device, e.g., a printer or UPS, which is not directly configured
on a computer, but can be reached through a network link.
Device monitoring capabilities are provided by device manufacturers via a Management Information Base
(MIB) text file, which describes the structure of the device management data. MIB files use a hierarchical
namespace containing object identifiers (OID). Each OID identifies a property that can be read or written
via SNMP.
Desigo CC has an SNMP Manager feature for reading and writing information from SNMP agents.
See
SNMP Application Guide
(A6V10455382).
Web services
Using RESTful technology, Desigo CC provides alarm, object and time series data via web based services
for supervising management platforms or other third-party external applications.
21.2 Integration on automation level
The integration of third-party devices and systems on the automation level is appropriate when:
● Cross-communication to other PX or BACnet devices is needed
● System functions (e.g., alarms, trends, schedulers) are needed
The PX Open Platform comprises:
● PXC001.D system controller for the integration of KNX, Modbus, M-Bus and SCL via BACnet/LonTalk
● PXC001-E.D system controller for the integration of KNX, Modbus, M-Bus and SCL via BACnet/IP
● PXA40-RS1 and PXA40-RS2 option modules for additional data points
The automation stations have interfaces to RS232, RS485 and KNX.
Xworks Plus (XWP) is used to engineer all solutions. Various compounds and blocks are available.
The following solutions on the PX Open platform are available:
● PX KNX
● PX Modbus
● PX M-Bus
● PX SCL
● PX RS-Bus
● PX Pronto
● PX Open Platform (SDK)
Data points