User Manual
Table Of Contents
- 1 Cyber security disclaimer
- 2 Preconditions of this document
- 3 System overview
- 4 Desigo workflow, tools and programming
- 4.1 Coverage of the technical process
- 4.2 Coverage of the system
- 4.3 Main tasks
- 4.4 Tools for different roles
- 4.5 Working with libraries
- 4.6 Working in parallel and subcontracting
- 4.7 Workflow for primary systems
- 4.8 Workflow for room automation classic
- 4.9 Workflow for Desigo room automation
- 4.10 Desigo Configuration Module (DCM)
- 4.11 Desigo Xworks Plus (XWP)
- 4.12 Desigo Automation Building Tool (ABT)
- 4.13 Programming in D-MAP
- 5 Control concept
- 6 Technical view
- 7 Global objects and functions
- 8 Events and COV reporting
- 9 Alarm management
- 9.1 Alarm sources
- 9.2 Alarm example
- 9.3 Effects of BACnet properties on alarm response
- 9.4 Alarm response of the function blocks
- 9.5 Alarm functions
- 9.6 Alarm management by notification class
- 9.7 Alarm routing over the network
- 9.8 Alarm queuing
- 9.9 Common alarms
- 9.10 Alarm suppression
- 9.11 Alarm message texts
- 10 Calendars and schedulers
- 11 Trending
- 12 Reports
- 13 Data storage
- 14 Network architecture
- 15 Remote access
- 16 Management platform
- 17 Desigo Control Point
- 18 Automation stations
- 19 Logical I/O blocks
- 20 Room automation
- 21 Desigo Open
- 22 System configuration
- 22.1 Technical limits and limit values
- 22.2 Maximum number of elements in a network area
- 22.3 Desigo room automation system function group limits
- 22.4 Devices
- 22.4.1 PXC..D automation stations / system controllers
- 22.4.2 LonWorks system controllers
- 22.4.3 Automation stations with LonWorks integration
- 22.4.4 PX Open integration (PXC001.D/-E.D)
- 22.4.5 PX Open integration (PXC001.D/-E.D + PXA40-RS1)
- 22.4.6 PX Open integration (PXC001.D/-E.D + PXA40-RS2)
- 22.4.7 PX KNX integration (PXC001.D/-E.D)
- 22.4.8 TX Open integration (TXI1/2/2-S.OPEN)
- 22.4.9 Number of data points on Desigo room automation stations
- 22.4.10 Number of data points for PXC3
- 22.4.11 Number of data points for DXR1
- 22.4.12 Number of data points for DXR2
- 22.4.13 PXM20 operator unit
- 22.4.14 PXM10 operator unit
- 22.4.15 Desigo Control Point
- 22.4.16 PXG3.L and PXG3.M BACnet routers
- 22.4.17 SX OPC
- 22.4.18 Desigo CC
- 22.4.19 Desigo Insight
- 22.4.20 Desigo Xworks Plus (XWP)
- 22.4.21 Desigo Automation Building Tool (ABT)
- 22.5 Applications
- 23 Compatibility
- 23.1 Desigo version compatibility definition
- 23.2 Desigo system compatibility basics
- 23.2.1 Compatibility with BACnet standard
- 23.2.2 Compatibility with operating systems
- 23.2.3 Compatibility with SQL servers
- 23.2.4 Compatibility with Microsoft Office
- 23.2.5 Compatibility with web browsers
- 23.2.6 Compatibility with ABT Go
- 23.2.7 Compatibility with VMware (virtual infrastructure)
- 23.2.8 Compatibility of software/libraries on the same PC
- 23.2.9 Hardware and firmware compatibility
- 23.2.10 Backward compatibility
- 23.2.11 Engineering compatibility
- 23.2.12 Compatibility with Desigo Configuration Module (DCM)
- 23.2.13 Compatibility with Desigo PX / Desigo room automation
- 23.2.14 Compatibility with Desigo RX tool
- 23.2.15 Compatibility with TX-I/O
- 23.2.16 Compatibility with TX Open
- 23.3 Desigo Control Point
- 23.4 Upgrading from Desigo V6.2 Update (or Update 2) to V6.2 Update 3
- 23.5 Siemens WEoF clients
- 23.6 Migration compatibility
- 23.7 Hardware requirements of Desigo software products
- 24 Desigo PXC4 and PXC5
- 25 Compatibility of Desigo V6.2 Update 3 with PXC4 and PXC5
Desigo Open
Desigo RXB
21
306 | 351 CM110664en_07
21 Desigo Open
Desigo Open lets you integrate devices and systems from different manufacturers into the Desigo system.
Integration with Desigo Open offers:
● Standardized automated functions, operating and monitoring of the entire building
● Single-station operation, common view and display. Simplified multidisciplinary operation, common
reporting and common alarm management.
● Peer-to-peer interaction, communication on the automation level, automated interactions and data
exchange
● Comfort combined with lower energy consumption. New opportunities to save energy with systems that
communicate among themselves. Improved performance, efficiency evaluation, flexibility and ability to
modify system operation and configuration without re-cabling or new hardware.
● Engineering of integrated solutions in Xworks Plus (XWP)
● Reduced risk thanks to standard solutions. Clear functions that cover the most important standard
protocols.
Topology
Third-party devices and systems can be integrated with Desigo on all levels.
Which protocols does Desigo support?
Desigo Open System Protocol
Desigo CC SCADA, etc.
PX Open Modbus, KNX/EIB, LonWorks, M-Bus, SCL, etc.
TX Open Modbus, M-Bus, GENIbus, etc.
Room level (Desigo room automation and RX) DALI, KNX, EnOcean, LonWorks
Which plant sections can be integrated into Desigo on which level?
L W
ON ORKS
System controller
TX-I/O-
Modules
Desigo CC
QAX9..
EnOcean
Room units
PX Open
PXC50/100/200..D
Modular
TX Open
PX KNX
System conroller
PXC001..D
PXC...D
Compact
RXZ97.1/KNX
RS232
RS485
Desigo Control Point
Adapter
BACnet
Third-party system
Field and room level Automation level Management level
BACnet/LonTalk or BACnet/IP
Third-party system
KNX S-Mode / EIB or Bus
L W
ON ORKS
Third-party system
KNX/EIB
Third-party system
RXB
Room controller
Third-party system
Peer-to-peer communication via BACnet
PXC001..D