User Manual
Table Of Contents
- 1 Cyber security disclaimer
- 2 Preconditions of this document
- 3 System overview
- 4 Desigo workflow, tools and programming
- 4.1 Coverage of the technical process
- 4.2 Coverage of the system
- 4.3 Main tasks
- 4.4 Tools for different roles
- 4.5 Working with libraries
- 4.6 Working in parallel and subcontracting
- 4.7 Workflow for primary systems
- 4.8 Workflow for room automation classic
- 4.9 Workflow for Desigo room automation
- 4.10 Desigo Configuration Module (DCM)
- 4.11 Desigo Xworks Plus (XWP)
- 4.12 Desigo Automation Building Tool (ABT)
- 4.13 Programming in D-MAP
- 5 Control concept
- 6 Technical view
- 7 Global objects and functions
- 8 Events and COV reporting
- 9 Alarm management
- 9.1 Alarm sources
- 9.2 Alarm example
- 9.3 Effects of BACnet properties on alarm response
- 9.4 Alarm response of the function blocks
- 9.5 Alarm functions
- 9.6 Alarm management by notification class
- 9.7 Alarm routing over the network
- 9.8 Alarm queuing
- 9.9 Common alarms
- 9.10 Alarm suppression
- 9.11 Alarm message texts
- 10 Calendars and schedulers
- 11 Trending
- 12 Reports
- 13 Data storage
- 14 Network architecture
- 15 Remote access
- 16 Management platform
- 17 Desigo Control Point
- 18 Automation stations
- 19 Logical I/O blocks
- 20 Room automation
- 21 Desigo Open
- 22 System configuration
- 22.1 Technical limits and limit values
- 22.2 Maximum number of elements in a network area
- 22.3 Desigo room automation system function group limits
- 22.4 Devices
- 22.4.1 PXC..D automation stations / system controllers
- 22.4.2 LonWorks system controllers
- 22.4.3 Automation stations with LonWorks integration
- 22.4.4 PX Open integration (PXC001.D/-E.D)
- 22.4.5 PX Open integration (PXC001.D/-E.D + PXA40-RS1)
- 22.4.6 PX Open integration (PXC001.D/-E.D + PXA40-RS2)
- 22.4.7 PX KNX integration (PXC001.D/-E.D)
- 22.4.8 TX Open integration (TXI1/2/2-S.OPEN)
- 22.4.9 Number of data points on Desigo room automation stations
- 22.4.10 Number of data points for PXC3
- 22.4.11 Number of data points for DXR1
- 22.4.12 Number of data points for DXR2
- 22.4.13 PXM20 operator unit
- 22.4.14 PXM10 operator unit
- 22.4.15 Desigo Control Point
- 22.4.16 PXG3.L and PXG3.M BACnet routers
- 22.4.17 SX OPC
- 22.4.18 Desigo CC
- 22.4.19 Desigo Insight
- 22.4.20 Desigo Xworks Plus (XWP)
- 22.4.21 Desigo Automation Building Tool (ABT)
- 22.5 Applications
- 23 Compatibility
- 23.1 Desigo version compatibility definition
- 23.2 Desigo system compatibility basics
- 23.2.1 Compatibility with BACnet standard
- 23.2.2 Compatibility with operating systems
- 23.2.3 Compatibility with SQL servers
- 23.2.4 Compatibility with Microsoft Office
- 23.2.5 Compatibility with web browsers
- 23.2.6 Compatibility with ABT Go
- 23.2.7 Compatibility with VMware (virtual infrastructure)
- 23.2.8 Compatibility of software/libraries on the same PC
- 23.2.9 Hardware and firmware compatibility
- 23.2.10 Backward compatibility
- 23.2.11 Engineering compatibility
- 23.2.12 Compatibility with Desigo Configuration Module (DCM)
- 23.2.13 Compatibility with Desigo PX / Desigo room automation
- 23.2.14 Compatibility with Desigo RX tool
- 23.2.15 Compatibility with TX-I/O
- 23.2.16 Compatibility with TX Open
- 23.3 Desigo Control Point
- 23.4 Upgrading from Desigo V6.2 Update (or Update 2) to V6.2 Update 3
- 23.5 Siemens WEoF clients
- 23.6 Migration compatibility
- 23.7 Hardware requirements of Desigo software products
- 24 Desigo PXC4 and PXC5
- 25 Compatibility of Desigo V6.2 Update 3 with PXC4 and PXC5
Room automation
Desigo room automation
20
298 | 351 CM110664en_07
PXC3.E72 PXC3.E72A PXC3.E75 PXC3.E75A PXC3.E16A
Typical number of rooms / room
segments
4/8 4/8 8/16 8/16 n/a
System communication
BACnet/IP BACnet/IP BACnet/IP BACnet/IP BACnet/IP
HMI automation level
QMX3
• • • •
QMX7
• • • • •
Web based test and setup tool
• • • • •
System functions (BACnet)
BACnet profiles
B-ASC B-ASC B-ASC B-ASC B-ASC
Programming
• • • • •
Peripheral bus
Bus for I/O module
• • • •
KNX PL-Link
1
/ KNX S-Mode
• • • •
DALI
• • •
Maximum configuration
Number of I/O data points
2
140 140 280 280 64
Inputs/Outputs for TX I/O modules
72 72 200 200 0
Devices on KNX PL-Link
64 64 64 64 0
DALI ballasts
64 64 64
Integrated power supply for KNX (mA)
160 160 160 160 n/a
Key
1
Dedicated devices with KNX PL-Link.
2
Total number of data points used by TX-I/O, KNX PL-Link and DALI. For details, see chapter
System Configuration
.
TX-I/O modules
TX-I/O modules (TXM1) help connect field devices to the PXC3 room automation station. Bus supply and
interface modules (TXS1, TXA1) are available as an accessory.
The following TX-I/O modules can be used with the PXC3 room automation station:
● TXM1.8T: Triac module with 8 outputs (AC 24 V) to control thermal and motorized valve actuators (AC
24 V) for up to 4 actuators (3-point output) or 8 actuators (permanent contact or pulse width
modulation).
● TXM1.6RL: Bistable relay module to switch lighting for up to 6 data points.
● TXM1.8RB: Relay module to control blind motors for up to 2 motors (3 end switches) or 4 motors (2 end
switches).
● TXM1.16D: Digital input modules for up to 16 data points.
● TXM1.8D: Digital input modules for up to 8 data points.