User Manual
Table Of Contents
- 1 Cyber security disclaimer
- 2 Preconditions of this document
- 3 System overview
- 4 Desigo workflow, tools and programming
- 4.1 Coverage of the technical process
- 4.2 Coverage of the system
- 4.3 Main tasks
- 4.4 Tools for different roles
- 4.5 Working with libraries
- 4.6 Working in parallel and subcontracting
- 4.7 Workflow for primary systems
- 4.8 Workflow for room automation classic
- 4.9 Workflow for Desigo room automation
- 4.10 Desigo Configuration Module (DCM)
- 4.11 Desigo Xworks Plus (XWP)
- 4.12 Desigo Automation Building Tool (ABT)
- 4.13 Programming in D-MAP
- 5 Control concept
- 6 Technical view
- 7 Global objects and functions
- 8 Events and COV reporting
- 9 Alarm management
- 9.1 Alarm sources
- 9.2 Alarm example
- 9.3 Effects of BACnet properties on alarm response
- 9.4 Alarm response of the function blocks
- 9.5 Alarm functions
- 9.6 Alarm management by notification class
- 9.7 Alarm routing over the network
- 9.8 Alarm queuing
- 9.9 Common alarms
- 9.10 Alarm suppression
- 9.11 Alarm message texts
- 10 Calendars and schedulers
- 11 Trending
- 12 Reports
- 13 Data storage
- 14 Network architecture
- 15 Remote access
- 16 Management platform
- 17 Desigo Control Point
- 18 Automation stations
- 19 Logical I/O blocks
- 20 Room automation
- 21 Desigo Open
- 22 System configuration
- 22.1 Technical limits and limit values
- 22.2 Maximum number of elements in a network area
- 22.3 Desigo room automation system function group limits
- 22.4 Devices
- 22.4.1 PXC..D automation stations / system controllers
- 22.4.2 LonWorks system controllers
- 22.4.3 Automation stations with LonWorks integration
- 22.4.4 PX Open integration (PXC001.D/-E.D)
- 22.4.5 PX Open integration (PXC001.D/-E.D + PXA40-RS1)
- 22.4.6 PX Open integration (PXC001.D/-E.D + PXA40-RS2)
- 22.4.7 PX KNX integration (PXC001.D/-E.D)
- 22.4.8 TX Open integration (TXI1/2/2-S.OPEN)
- 22.4.9 Number of data points on Desigo room automation stations
- 22.4.10 Number of data points for PXC3
- 22.4.11 Number of data points for DXR1
- 22.4.12 Number of data points for DXR2
- 22.4.13 PXM20 operator unit
- 22.4.14 PXM10 operator unit
- 22.4.15 Desigo Control Point
- 22.4.16 PXG3.L and PXG3.M BACnet routers
- 22.4.17 SX OPC
- 22.4.18 Desigo CC
- 22.4.19 Desigo Insight
- 22.4.20 Desigo Xworks Plus (XWP)
- 22.4.21 Desigo Automation Building Tool (ABT)
- 22.5 Applications
- 23 Compatibility
- 23.1 Desigo version compatibility definition
- 23.2 Desigo system compatibility basics
- 23.2.1 Compatibility with BACnet standard
- 23.2.2 Compatibility with operating systems
- 23.2.3 Compatibility with SQL servers
- 23.2.4 Compatibility with Microsoft Office
- 23.2.5 Compatibility with web browsers
- 23.2.6 Compatibility with ABT Go
- 23.2.7 Compatibility with VMware (virtual infrastructure)
- 23.2.8 Compatibility of software/libraries on the same PC
- 23.2.9 Hardware and firmware compatibility
- 23.2.10 Backward compatibility
- 23.2.11 Engineering compatibility
- 23.2.12 Compatibility with Desigo Configuration Module (DCM)
- 23.2.13 Compatibility with Desigo PX / Desigo room automation
- 23.2.14 Compatibility with Desigo RX tool
- 23.2.15 Compatibility with TX-I/O
- 23.2.16 Compatibility with TX Open
- 23.3 Desigo Control Point
- 23.4 Upgrading from Desigo V6.2 Update (or Update 2) to V6.2 Update 3
- 23.5 Siemens WEoF clients
- 23.6 Migration compatibility
- 23.7 Hardware requirements of Desigo software products
- 24 Desigo PXC4 and PXC5
- 25 Compatibility of Desigo V6.2 Update 3 with PXC4 and PXC5
Room automation
Desigo room automation
20
CM110664en_07 293 | 351
Flat • • • •
2
•
2
Operating voltage
230V • • •
24V • • • • • • •
Inputs and outputs onboard
Digital inputs 1 1 1 1 1 1 1 1 2 2
Universal
inputs
2 2 2 2 2 2 2 2 4 4
Relay outputs 3 1 3
Triac outputs 4 4 4 4 6 6 6 8 8
Analog
outputs (DC
0...10 V)
3
3 1 1 1 2 2 2 4 4
Pressure
sensor
1 1 1 1
Maximum configuration
Number of
I/O data
points
4
30 30 30 30 60 30 30 60 60 60
Integrated
power supply
for KNX (mA)
50 50 50 50 50 50 50 50 50 50
Key
1
Cannot be combined with other applications.
2
Mounting via damper shaft.
3
Cannot be extended by KNX PL-Link inputs and outputs.
4
Total number of data point used by TX-I/O, KNX PL-Link and DALI. For details, see chapter
System Configuration
.
See
Compact room automation stations, BACnet/IP, 230 V DXR2.E10.., DXR2.E09.., DXR2.E09T..
(N9204).
See
Compact room automation stations, BACnet/IP, 24 V DXR2.E18.., DXR2.E12P..
(N9205).
See
Compact room automation stations, BACnet MS/TP, 230 V DXR2.M10.., DXR2.M09.., DXR2.M09T..
(N9206).
See
Compact room automation stations, BACnet MS/TP, 24 V DXR2.M11.., DXR2.M12P.., DXR2.M18..
(N9207).
DXR1 compact room automation stations
Communication
BACnet/IP
DXR1.E09PD
Z-112
DXR1.E09PD
Z-113
DXR1.E10PL-
112
DXR1.E10PL-
113
DXR1.E02PLZ
-112
BACnet MS/TP
1
DXR1.M09PD
Z-112
DXR1.M09PD
Z-113
Applications