User Manual
Table Of Contents
- 1 Cyber security disclaimer
- 2 Preconditions of this document
- 3 System overview
- 4 Desigo workflow, tools and programming
- 4.1 Coverage of the technical process
- 4.2 Coverage of the system
- 4.3 Main tasks
- 4.4 Tools for different roles
- 4.5 Working with libraries
- 4.6 Working in parallel and subcontracting
- 4.7 Workflow for primary systems
- 4.8 Workflow for room automation classic
- 4.9 Workflow for Desigo room automation
- 4.10 Desigo Configuration Module (DCM)
- 4.11 Desigo Xworks Plus (XWP)
- 4.12 Desigo Automation Building Tool (ABT)
- 4.13 Programming in D-MAP
- 5 Control concept
- 6 Technical view
- 7 Global objects and functions
- 8 Events and COV reporting
- 9 Alarm management
- 9.1 Alarm sources
- 9.2 Alarm example
- 9.3 Effects of BACnet properties on alarm response
- 9.4 Alarm response of the function blocks
- 9.5 Alarm functions
- 9.6 Alarm management by notification class
- 9.7 Alarm routing over the network
- 9.8 Alarm queuing
- 9.9 Common alarms
- 9.10 Alarm suppression
- 9.11 Alarm message texts
- 10 Calendars and schedulers
- 11 Trending
- 12 Reports
- 13 Data storage
- 14 Network architecture
- 15 Remote access
- 16 Management platform
- 17 Desigo Control Point
- 18 Automation stations
- 19 Logical I/O blocks
- 20 Room automation
- 21 Desigo Open
- 22 System configuration
- 22.1 Technical limits and limit values
- 22.2 Maximum number of elements in a network area
- 22.3 Desigo room automation system function group limits
- 22.4 Devices
- 22.4.1 PXC..D automation stations / system controllers
- 22.4.2 LonWorks system controllers
- 22.4.3 Automation stations with LonWorks integration
- 22.4.4 PX Open integration (PXC001.D/-E.D)
- 22.4.5 PX Open integration (PXC001.D/-E.D + PXA40-RS1)
- 22.4.6 PX Open integration (PXC001.D/-E.D + PXA40-RS2)
- 22.4.7 PX KNX integration (PXC001.D/-E.D)
- 22.4.8 TX Open integration (TXI1/2/2-S.OPEN)
- 22.4.9 Number of data points on Desigo room automation stations
- 22.4.10 Number of data points for PXC3
- 22.4.11 Number of data points for DXR1
- 22.4.12 Number of data points for DXR2
- 22.4.13 PXM20 operator unit
- 22.4.14 PXM10 operator unit
- 22.4.15 Desigo Control Point
- 22.4.16 PXG3.L and PXG3.M BACnet routers
- 22.4.17 SX OPC
- 22.4.18 Desigo CC
- 22.4.19 Desigo Insight
- 22.4.20 Desigo Xworks Plus (XWP)
- 22.4.21 Desigo Automation Building Tool (ABT)
- 22.5 Applications
- 23 Compatibility
- 23.1 Desigo version compatibility definition
- 23.2 Desigo system compatibility basics
- 23.2.1 Compatibility with BACnet standard
- 23.2.2 Compatibility with operating systems
- 23.2.3 Compatibility with SQL servers
- 23.2.4 Compatibility with Microsoft Office
- 23.2.5 Compatibility with web browsers
- 23.2.6 Compatibility with ABT Go
- 23.2.7 Compatibility with VMware (virtual infrastructure)
- 23.2.8 Compatibility of software/libraries on the same PC
- 23.2.9 Hardware and firmware compatibility
- 23.2.10 Backward compatibility
- 23.2.11 Engineering compatibility
- 23.2.12 Compatibility with Desigo Configuration Module (DCM)
- 23.2.13 Compatibility with Desigo PX / Desigo room automation
- 23.2.14 Compatibility with Desigo RX tool
- 23.2.15 Compatibility with TX-I/O
- 23.2.16 Compatibility with TX Open
- 23.3 Desigo Control Point
- 23.4 Upgrading from Desigo V6.2 Update (or Update 2) to V6.2 Update 3
- 23.5 Siemens WEoF clients
- 23.6 Migration compatibility
- 23.7 Hardware requirements of Desigo software products
- 24 Desigo PXC4 and PXC5
- 25 Compatibility of Desigo V6.2 Update 3 with PXC4 and PXC5
Room automation
Desigo room automation
20
CM110664en_07 291 | 351
Application
the central plant.
– Supply VAV flow deviation helps to optimize the fan speed by calculating
the airflow deviation through the supply VAV dampers
– Extract VAV flow deviation helps to optimize the fan speed by calculating
the airflow deviation through the extract VAV dampers
– Supply VAV flow saturation evaluation (air flow control loop cannot get
enough air to reach setpoint) evaluates the supply VAV saturation signals
from the rooms to optimize the fan speed
– Extract VAV flow saturation evaluation (air flow control loop cannot get
enough air to reach setpoint) evaluates the extract VAV saturation signals
from the rooms to optimize the fan speed
– Supply VAV setpoint evaluation with the summed setpoints of the supply
VAV the fan's speed can be set for an optimized fan speed when VAV
positions and VAV flow rates are not known
– Extract VAV setpoint evaluation with the summed setpoints of the extract
VAV the fan's speed can be set for an optimized fan speed when VAV
positions and VAV flow rates are not known
Loadable central functions (continued)
Application
Central functions ● 2x VAV supply fire emergency group with off, extract, pressurization or purge
● 1x Central weather station with:
– Outside temperature
– Outside brightness
– Outside solar radiation
– Outside wind speed
– Outside precipitation
● 2x Light manual central operation group
● 1x Light central control group for emergency situations
● 4x Shading central facade functions with:
– Central weather station brightness calculation supports facade automatic
function
– Glare protection function calculates the glare protection state by central
weather station for all facade
– Annual shading calculates the glare protection state for all facade by in-
formation from annual shading computer
– Thermal protection for unoccupied rooms by central global radiation
sensor on weather station
– Three delayed distribution groups for central blind commands for big
buildings
● 2x Shading manual central operation with 3 delayed distribution groups for
big buildings
● 1x Shading service ensures central commanding of blind group with high
priority
● 1x Shading central protection for all blinds with:
– Wind protection
– Precipitation protection
– Frost protection
– Three delayed distribution groups for big buildings
See
Application Catalog
.