User Manual
Table Of Contents
- 1 Cyber security disclaimer
- 2 Preconditions of this document
- 3 System overview
- 4 Desigo workflow, tools and programming
- 4.1 Coverage of the technical process
- 4.2 Coverage of the system
- 4.3 Main tasks
- 4.4 Tools for different roles
- 4.5 Working with libraries
- 4.6 Working in parallel and subcontracting
- 4.7 Workflow for primary systems
- 4.8 Workflow for room automation classic
- 4.9 Workflow for Desigo room automation
- 4.10 Desigo Configuration Module (DCM)
- 4.11 Desigo Xworks Plus (XWP)
- 4.12 Desigo Automation Building Tool (ABT)
- 4.13 Programming in D-MAP
- 5 Control concept
- 6 Technical view
- 7 Global objects and functions
- 8 Events and COV reporting
- 9 Alarm management
- 9.1 Alarm sources
- 9.2 Alarm example
- 9.3 Effects of BACnet properties on alarm response
- 9.4 Alarm response of the function blocks
- 9.5 Alarm functions
- 9.6 Alarm management by notification class
- 9.7 Alarm routing over the network
- 9.8 Alarm queuing
- 9.9 Common alarms
- 9.10 Alarm suppression
- 9.11 Alarm message texts
- 10 Calendars and schedulers
- 11 Trending
- 12 Reports
- 13 Data storage
- 14 Network architecture
- 15 Remote access
- 16 Management platform
- 17 Desigo Control Point
- 18 Automation stations
- 19 Logical I/O blocks
- 20 Room automation
- 21 Desigo Open
- 22 System configuration
- 22.1 Technical limits and limit values
- 22.2 Maximum number of elements in a network area
- 22.3 Desigo room automation system function group limits
- 22.4 Devices
- 22.4.1 PXC..D automation stations / system controllers
- 22.4.2 LonWorks system controllers
- 22.4.3 Automation stations with LonWorks integration
- 22.4.4 PX Open integration (PXC001.D/-E.D)
- 22.4.5 PX Open integration (PXC001.D/-E.D + PXA40-RS1)
- 22.4.6 PX Open integration (PXC001.D/-E.D + PXA40-RS2)
- 22.4.7 PX KNX integration (PXC001.D/-E.D)
- 22.4.8 TX Open integration (TXI1/2/2-S.OPEN)
- 22.4.9 Number of data points on Desigo room automation stations
- 22.4.10 Number of data points for PXC3
- 22.4.11 Number of data points for DXR1
- 22.4.12 Number of data points for DXR2
- 22.4.13 PXM20 operator unit
- 22.4.14 PXM10 operator unit
- 22.4.15 Desigo Control Point
- 22.4.16 PXG3.L and PXG3.M BACnet routers
- 22.4.17 SX OPC
- 22.4.18 Desigo CC
- 22.4.19 Desigo Insight
- 22.4.20 Desigo Xworks Plus (XWP)
- 22.4.21 Desigo Automation Building Tool (ABT)
- 22.5 Applications
- 23 Compatibility
- 23.1 Desigo version compatibility definition
- 23.2 Desigo system compatibility basics
- 23.2.1 Compatibility with BACnet standard
- 23.2.2 Compatibility with operating systems
- 23.2.3 Compatibility with SQL servers
- 23.2.4 Compatibility with Microsoft Office
- 23.2.5 Compatibility with web browsers
- 23.2.6 Compatibility with ABT Go
- 23.2.7 Compatibility with VMware (virtual infrastructure)
- 23.2.8 Compatibility of software/libraries on the same PC
- 23.2.9 Hardware and firmware compatibility
- 23.2.10 Backward compatibility
- 23.2.11 Engineering compatibility
- 23.2.12 Compatibility with Desigo Configuration Module (DCM)
- 23.2.13 Compatibility with Desigo PX / Desigo room automation
- 23.2.14 Compatibility with Desigo RX tool
- 23.2.15 Compatibility with TX-I/O
- 23.2.16 Compatibility with TX Open
- 23.3 Desigo Control Point
- 23.4 Upgrading from Desigo V6.2 Update (or Update 2) to V6.2 Update 3
- 23.5 Siemens WEoF clients
- 23.6 Migration compatibility
- 23.7 Hardware requirements of Desigo software products
- 24 Desigo PXC4 and PXC5
- 25 Compatibility of Desigo V6.2 Update 3 with PXC4 and PXC5
Automation stations
Operating states
18
232 | 351 CM110664en_07
●
STOP
: The D-MAP program is stopped.
●
RUN
: The D-MAP program runs.
●
KOMA
: The automation station is in a prolonged sleep mode.
The following figure shows the operating states and the associated transitions:
Operating states
Mains off
● No power supply
STOP
● I/O scan active
● Ready for wiring test (only possible without D-MAP program loaded) (PXM20, for PTM modules only)
● D-MAP program processing stopped
● Communication with XWP: Master reset, complete loading and delta loading allowed
● BACnet communication with Desigo CC and PXM20: ReadProperty, WriteProperty, Who-Has, COVs,
EventNotification, AcknowledgeAlarm GetEventInformation
● COVs: For values changed by the operator, values cannot be changed by the program
● Alarming: Alarm monitoring inactive, no new alarms or events are generated (the device info object can
still generate alarms and system events). Notification of saved alarms and events is possible if recipient
lists are set up. GetEventInformation and AcknowledgeAlarm possible.
● Primary server in the STOP state: Primary server is not active, that is, no life check, no time
synchronization and no replication of global objects
● Backup server in the STOP state: The backup server is not active, that is, no time synchronization and
no replication of global objects by primary server. The backup server will not accept changes to global
objects by a client.
RUN
● I/O scan active
● Wiring test not allowed
● D-MAP program processing active
● Communication with XWP: Master reset and complete loading not allowed, delta loading allowed
STOP
Mains OFF
BACnet: Download
required
COMA
RUN
BACnet: Operational
BACnet: Operational
15: Delta loading
16: Delta loading
7: Restart 9: Reset
4: RUN Cmd
5: STOP Cmd
7: Restart 9: Reset
14: Load
13: Master reset
10: Fatal Error
12: Reanimation
11: Fatal Error
1: Power failure 2: Power restored STOP
1: Power failure
2: Power restored RUN
1: Power failure
2: Power restored COMA