User Manual
Table Of Contents
- 1 Cyber security disclaimer
- 2 Preconditions of this document
- 3 System overview
- 4 Desigo workflow, tools and programming
- 4.1 Coverage of the technical process
- 4.2 Coverage of the system
- 4.3 Main tasks
- 4.4 Tools for different roles
- 4.5 Working with libraries
- 4.6 Working in parallel and subcontracting
- 4.7 Workflow for primary systems
- 4.8 Workflow for room automation classic
- 4.9 Workflow for Desigo room automation
- 4.10 Desigo Configuration Module (DCM)
- 4.11 Desigo Xworks Plus (XWP)
- 4.12 Desigo Automation Building Tool (ABT)
- 4.13 Programming in D-MAP
- 5 Control concept
- 6 Technical view
- 7 Global objects and functions
- 8 Events and COV reporting
- 9 Alarm management
- 9.1 Alarm sources
- 9.2 Alarm example
- 9.3 Effects of BACnet properties on alarm response
- 9.4 Alarm response of the function blocks
- 9.5 Alarm functions
- 9.6 Alarm management by notification class
- 9.7 Alarm routing over the network
- 9.8 Alarm queuing
- 9.9 Common alarms
- 9.10 Alarm suppression
- 9.11 Alarm message texts
- 10 Calendars and schedulers
- 11 Trending
- 12 Reports
- 13 Data storage
- 14 Network architecture
- 15 Remote access
- 16 Management platform
- 17 Desigo Control Point
- 18 Automation stations
- 19 Logical I/O blocks
- 20 Room automation
- 21 Desigo Open
- 22 System configuration
- 22.1 Technical limits and limit values
- 22.2 Maximum number of elements in a network area
- 22.3 Desigo room automation system function group limits
- 22.4 Devices
- 22.4.1 PXC..D automation stations / system controllers
- 22.4.2 LonWorks system controllers
- 22.4.3 Automation stations with LonWorks integration
- 22.4.4 PX Open integration (PXC001.D/-E.D)
- 22.4.5 PX Open integration (PXC001.D/-E.D + PXA40-RS1)
- 22.4.6 PX Open integration (PXC001.D/-E.D + PXA40-RS2)
- 22.4.7 PX KNX integration (PXC001.D/-E.D)
- 22.4.8 TX Open integration (TXI1/2/2-S.OPEN)
- 22.4.9 Number of data points on Desigo room automation stations
- 22.4.10 Number of data points for PXC3
- 22.4.11 Number of data points for DXR1
- 22.4.12 Number of data points for DXR2
- 22.4.13 PXM20 operator unit
- 22.4.14 PXM10 operator unit
- 22.4.15 Desigo Control Point
- 22.4.16 PXG3.L and PXG3.M BACnet routers
- 22.4.17 SX OPC
- 22.4.18 Desigo CC
- 22.4.19 Desigo Insight
- 22.4.20 Desigo Xworks Plus (XWP)
- 22.4.21 Desigo Automation Building Tool (ABT)
- 22.5 Applications
- 23 Compatibility
- 23.1 Desigo version compatibility definition
- 23.2 Desigo system compatibility basics
- 23.2.1 Compatibility with BACnet standard
- 23.2.2 Compatibility with operating systems
- 23.2.3 Compatibility with SQL servers
- 23.2.4 Compatibility with Microsoft Office
- 23.2.5 Compatibility with web browsers
- 23.2.6 Compatibility with ABT Go
- 23.2.7 Compatibility with VMware (virtual infrastructure)
- 23.2.8 Compatibility of software/libraries on the same PC
- 23.2.9 Hardware and firmware compatibility
- 23.2.10 Backward compatibility
- 23.2.11 Engineering compatibility
- 23.2.12 Compatibility with Desigo Configuration Module (DCM)
- 23.2.13 Compatibility with Desigo PX / Desigo room automation
- 23.2.14 Compatibility with Desigo RX tool
- 23.2.15 Compatibility with TX-I/O
- 23.2.16 Compatibility with TX Open
- 23.3 Desigo Control Point
- 23.4 Upgrading from Desigo V6.2 Update (or Update 2) to V6.2 Update 3
- 23.5 Siemens WEoF clients
- 23.6 Migration compatibility
- 23.7 Hardware requirements of Desigo software products
- 24 Desigo PXC4 and PXC5
- 25 Compatibility of Desigo V6.2 Update 3 with PXC4 and PXC5
Network architecture
BACnet architecture (MLN & ALN)
14
190 | 351 CM110664en_07
BACnet directly over ethernet, ZigBee or ARCnet is not supported.
Application layer
The BACnet application layer defines services, objects and their characteristics. From the network
viewpoint, the Device object is important. The object ID and the object name must be unique within the
BACnet internetwork.
Device ID
The Device ID is the object ID of the BACnet device object.
The device ID is divided into the following categories:
Category Device ID Description
Object type Object instance
2 bit 10 bit 10 bit
Unconfigured DEVICE 00 0000000000 0000000000 All unconfigured devices
Class A DEVICE 00 xxxxxxxxxx xxxxxxxxxx (1...1048576) Third-party devices
Class B1 DEVICE 01 Device number Stationary operator units
(Desigo CC)
0000000000 xxxxxxxxxx
(1...999)
Class B2 DEVICE 01 Device number Mobile operator units / tools
(PXM30/40/50-E)
0000000001 xxxxxxxxxx
(1...999)
Class B3 DEVICE 01 Device number System devices (BACnet
router)
0000000010 xxxxxxxxxx
(1...999)
Class C DEVICE 10 Site number Device number Automation stations (PXC…)
System controllers (PXC…)
xxxxxxxxxx
(1...999)
xxxxxxxxxx
(1...999)
Class D DEVICE 11 xxxxxxxxxx xxxxxxxxxx (1...1048576) Reserved
Device name
Application Layer
Network Layer
ISO8802-2 Type 1
(IEEE802.2)
Ethernet
ISO8802-3
(IEEE802.3)
ARCNET EIA-485 EIA-232
LonTalk
(EIA 709.1)
PTPMS/TP
BACnet Layers
Application Layer
Network Layer
Data Link Layer
Physical Layer
Supported in Desigo
ISO/OSI Layers
Ethernet
ISO8802-3
(IEEE802.3)
BVLL
UDP/IP
ISO8802-2 Type 1
(IEEE802.2)
TP/FT 10
(EIA-709.1)
VMAC
BVLLv6
UDP/IPv6
Only via PXG3 router
BZLL
ZigBee
IEEE
802.15.4
Application Layer
Network Layer
PTPIPLonTalk MSTP